Appliance Start And Use - Jolly Mec I-DEA IDRO Installation, Use And Maintenance Manual

Pellet fired stove with boiler
Table of Contents

Advertisement

08.3

APPLIANCE START AND USE

After professionally installing the room ventilation system, the fume exhaust system, the hydraulic system and electrical system according
to the relevant regulations, the CAT can commission the first start up.
After passing the Service Technician's inspection, the tank can be filled with pellets of the recommended quality, desired temperature and
power set (we recommend setting level 3) and the device turned on with Button 3. The stove will run until the room probe, thermostat or
accumulation tank probe temperature values are reached, according to the set configuration. When the set temperatures are reached,
the stove switches to ECONOMY mode until a new request is sent by the probes.
When running in ECONOMY mode, the water circulation pump is off and only turns back on to dissipate heat when stove water reaches
80°C, turning back off at 75°C. For this reason, any system zone valves must be adequately controlled to permit water circulation with
room temperature. For this purpose, the Jolly Mec ZONE MODULE (available separately) resolves the problem of alarms due to stove
water overheating when zone valves are closed.
Activate STAND-BY mode in MENU 5 to turn off the stove when all probe temperatures are reached for a time over that set in MENU 5
(DELAY OFF). The stove is not actually off but is waiting to turn back on at a new probe request.
The STAND-BY function in system configurations 5 and 7, summer and winter mode, and configuration 6, summer mode, is automatically
activated. When the Puffer and/or Boiler tank has reached the set temperature, the boiler will turn off and turn back on when the
temperature measured by the Puffer Lo probe or Boiler probe is 10°C lower than the set temperature. The differential value can be
modified by the CAT.
Set SET CHRONO – MENU 2 to time operation start and stop. The crono can be quickly started by pressing Button 1 and 2 on the main
display screen. CHRONO and STAND-BY modes cannot be activated simultaneously. The CHRONO function should be considered
as a timer function, while STAND-BY is a temperature function. It is possible to set the desired temperature level for each time band.
The message ORDINARY SERVICE is periodically displayed, every 100 hours of operation, to remind the user to clean the stove
thoroughly CHAP.08.6 - ROUTINE MAINTENANCE (By the Customer). Press Button 3 in the main screen to cancel the message.
In the event of alarms and/or manual pellet load from MENU 7, message CLEAN BRAZIER is a warning to be sure not to turn on
the stove with excessive pellets in the brazier. To cancel the message, clean the brazier and press and hold down Button 3 for three
seconds. Cleaning the firebox obviously involves opening the combustion chamber door, an important step to reset the CLEAN FIREBOX
message, as it is not possible to restart the device without opening and closing the door. This restriction is managed by a door probe,
installed on the bottom front part of the stove, which also checks that the door is opened during operations. If the user wishes to voluntarily
open the door, the problem will cause the device to shut down immediately.
The stove also has ANTIFREEZE AND ANTI-JAM functions. The first turns on when stove water temperature is 5°C, starting the water
circulator until temperature increases 1°C. If a THERMOSTAT MODULE is used, this function turns on when room temperature reaches
the anti-freeze temperature set in the module so that the stove runs a start cycle and runs until room temperatures increases 2°C. The
ANTI-JAM function starts the water circulator after 24 hours of disuse for 30". In addition to the water circulator, if the stove is installed in
configurations 6 or 7, the hot water boiler 3-way diverter valve is also started. If the ZONE MODULE is installed, all actuators connected
to outputs are run for 30".
The shutdown phase takes about 20 minutes and the circulator is activated in this interval to perform a heat dissipation cycle.
WARNING
The installation technician must attend appliance inspection since system components may require adjustments
not pertinent to the CAT at this time.
Any additional work by the CAT due to the failure to complete the above adjustments during initial inspection is at the user's
expense.
NOTE
We recommend activating STAND-BY mode when permitted by factory and/or use conditions. Frequent starts
and stops may cause appliance malfunctions, possible no start alarms and waste energy and fuel.
37