York Geysir User Manual page 26

Residential heat pumps
Table of Contents

Advertisement

Available languages

Available languages

3 .2 .3
Sub-menu HEATCURVE
In the HEATCURVE menu the settings that affect the
indoor temperature are made. For further information,
see the "About your heat pump" section.
Menu text
CURVE
MIN
MAX
CURVE 5
CURVE 0
CURVE - 5
HEATSTOP
REDUCTION
ROOM FACTOR
(Only displayed if
a Room sensor is
installed.)
POOL
(Only displayed if an
Expansion card is
installed)
POOL HYSTERES
(Only displayed if an
Expansion card is
installed)
26
ENGLISH
Description
The set value indicates the supply line
temperature of the water that is transported
to the heating system at an outdoor tempe-
rature of 0°C.
Sets the lowest permitted supply tempe-
rature.
Sets the highest permitted supply tempe-
rature.
Used to adjust the heat curve at an outdo-
or temperature of +5°C.
Used to adjust the heat curve at an outdo-
or temperature of 0°C.
Used to adjust the heat curve at an outdo-
or temperature of -5°C.
This function stops all production of heat
when the outdoor temperature is equal to,
or higher than, the set heat stop value.
The temperature can be lowered using an
outside timer. The control computer lowers
the indoor temperature using the set value.
Determines how large an impact the room
temperature is to have when calculating
the supply temperature. For underfloor
heating we recommend a setting between
1-3 and for radiator heating between 2-4.
The temperature in the pool is controlled
by a separate sensor regardless of the
heating and hot water system.
The temperature range between start
and stop for the pool's heat production.
HEATCURVE
CURVE
MIN
MAX
CURVE 5
CURVE 0
CURVE -5
HEATSTOP
Adjusted by:
By the customer,
if necessary.
By the customer,
if necessary.
By the customer,
if necessary.
By the customer,
if necessary.
By the customer,
if necessary.
By the customer,
if necessary.
By the customer,
if necessary.
By the customer,
if necessary.
Factory setting: 2
(interval:
0 - 4)
(0 = no impact,
4 = large impact)
By the customer, if
necessary.
Authorized installer.
Adjusted for each
installation.
40
C
°
22
C
°
70
C
°
0
C
°
0
C
°
0
C
°
17
C
°