York Geysir User Manual page 28

Residential heat pumps
Table of Contents

Advertisement

Available languages

Available languages

3 .2 .5
Sub-menu TEMPERATURE
I
n the TEMPERATURE menu you are able to view the
various temperatures that the installation has had. All
temperatures are stored 100 minutes (factory setting)
back in time so that they can also be displayed in the
form of graphs.
Menu text
OUTDOOR
ROOM
SUPPLY PIPE
RETURN PIPE
HOT WATER
INTEGRAL
BRINE OUT
BRINE IN
POOL
(Only displayed if an
Expansion card is installed)
SHUNT GROUP
(Only displayed if an
Expansion card is installed)
COOLING
(Only displayed if an
Expansion card is installed)
CURRENT
(Only displayed if an
Expansion card is installed)
28
ENGLISH
Description
Shows the actual outdoor temperature.
If ROOM shows 20°C the heat curve is unaffec-
ted. If ROOM shows higher or lower, this indi-
cates that the heat curve has been adjusted up
or down to change the indoor temperature.
Shows the actual supply temperature.
(The desired value is shown between brac-
kets)
Read the "Regulation information" section
for more information.
(In operating mode ADD.HEAT the stop
temperature for hot water production is
shown in brackets, increased by 5°.)
Shows the read return temperature. (The
highest permitted temperature is shown
between brackets.)
Shows the actual hot water temperature.
Heat production is controlled by a calculated
demand that is automatically calculated when
the installation is in operation. The value for
the integral displays the heating system's
actual energy balance. Read the "Regulation
information" section for more information.
The temperature of the brine circuit
going out from the heat pump.
The temperature of the brine from the heat
source.
Shows the actual pool temperature.
The set pool temperature is shown in brackets.
Shows the actual supply temperature. The cal-
culated supply temperature to the shunt group
is within brackets.
Shows the actual supply temperature. The set
point value is shown in brackets.
Shows the actual current consumption. The set
value for MAX CURRENT is shown between
brackets.
TEMPERATURE
OUTDOOR
ROOM
SUPPLY PIPE
RETURN PIPE
HOT WATER
INTEGRAL
BRINE OUT
Adjusted by:
By the customer,
if necessary.
Not adjustable
(The computer
calculates the
temperature requi-
red to maintain
the indoor tempe-
rature.)
Authorized ins-
taller.
Adjusted for each
installation.
Not adjustable.
Not adjustable.
Not adjustable.
Not adjustable.
Not adjustable.
Not adjustable.
Not adjustable.
Not adjustable.
0°C
20°C
38(40)°C
34(48)°C
52°C
-660
-7°C