York Geysir User Manual page 30

Residential heat pumps
Table of Contents

Advertisement

Available languages

Available languages

3 .2 .7
Sub-menu OPERAT .TIME, Geysir Air
This menu is specific to Geysir Air.
In the OPERAT.TIME menu you are able to view the
operating time of the installation. Operating times cannot
be reset but are accumulated during the service life of
the heat pump. The control computer calculates the ope-
rating time in minutes but only complete hours are shown in the display.
Menu text
HEATPUMP
ADD. HEAT 1
ADD. HEAT 2
ADD. HEAT 3
HOT WATER
The auxiliary heater is made up of an electric heating element on the supply pipe that has
three different outputs, ADD.HEAT 1 (3 kW), ADD.HEAT 2 (6 kW) and ADD.HEAT 3 (6 kW),
and can be controlled in five steps: For three phase 400V heat pumps the outputs are in the
different steps:
Step 1 = ADD.HEAT 1 = 3 kW
l
Step 2 = ADD.HEAT 2 = 6 kW
l
Step 3 = ADD.HEAT 1 + ADD.HEAT 2 = 9 kW
l
Step 4 = ADD.HEAT 2 + ADD.HEAT 3 = 12 kW
l
Step 5 = ADD.HEAT 1 + ADD.HEAT 2 + ADD.HEAT 3 = 15 kW
l
For single phase 230V heat pumps the additional heat output can be controlled three steps
with the following effects:
Step 1 = ADD.HEAT 1 = 1.5 kW
l
Step 2 = ADD.HEAT 2 = 3 kW
l
Step 3 = ADD.HEAT 1 + ADD.HEAT 2 = 4.5 kW
l
30
ENGLISH
Description
Shows the total time in hours that the heat
pump has been in operation since installa-
tion. The number of operating hours inclu-
des the time for both heat production and
hot water production.
Shows the total time in hours that the auxi-
liary heater (3 kW) has been in operation
since installation.
Shows the total time in hours that the auxi-
liary heater (6 kW) has been in operation
since installation.
Showsthe total time in hours that the auxi-
liary heater (6 kW) has been in operation
since installation.
Shows a part of the time that is included
in the HEAT PUMP value. The number of
hours that hot water production has been
in operation since installation are shown
here.
OPERAT.TIME
HEATPUMP
ADD. HEAT 1
ADD. HEAT 2
ADD. HEAT 3
HOT WATER
Adjusted by:
Not adjustable.
Not adjustable.
Not adjustable.
Not adjustable.
Not adjustable.
0H
0H
0H
0H
0H