Split-system heat pumps 13 seer – r-410a – single phase

Advertisement

TECHNICAL
TECHNICAL
GUIDE
GUIDE
SPLIT-SYSTEM HEAT PUMPS
13 SEER – R-410A – Single Phase
MODELS:
GHGD18 THRU 60
(1.5 THRU 5 NOMINAL TONS)
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
5-year limited parts warranty.
5-year limited compressor warranty.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The 13 SEER Series unit is the outdoor part of a versatile cli-
mate system. It is designed with a matching indoor coil compo-
nent from Johnson Controls Unitary Products. Available for
typical applications this climate system is supported with acces-
sories and documents to serve specific functions.
FEATURES
• Quality Condenser Coils - The coil is constructed of copper
tubing and enhanced aluminum fins for increased efficiency
and corrosion protection.
• Protected Compressor - The compressor is internally pro-
tected against high pressure, temperature, and externally by
a factory installed high pressure switch. This is accomplished
by the simultaneous operation of high pressure relief valve
and a temperature sensor which protects the compressor if
undesirable operating conditions occur. A liquid line filter-
drier further protects the compressor.
• Durable Finish - The cabinet is made of pre-painted steel.
The pre-treated galvanized steel provides a better paint to
steel bond, which resists corrosion and rust creep. Special
primer formulas and matted-textured finish insure less fading
when exposed to sunlight.
• Lower Installed Cost - Installation time and costs are
reduced by easy power and control wiring connections.
Available in sweat connect models only. The unit contains
enough refrigerant for matching indoor coils and 15 feet of
interconnecting piping. The small base dimension means
less space is required on the ground or roof.
• Top Discharge - The warm air from the top mounted fan is
blown up away from the structure and any landscaping. This
allows compact location on multi-unit applications.
• Low Operating Sound Level - The upward air flow carries
the normal operating noise away from the living area. The
rigid top panel effectively isolates any motor sound. Isolator
mounted compressor and the rippled fins of the condenser
coil muffle the normal fan motor and compressor operating
sounds.
• Low Maintenance - Long life permanently lubricated motor-
bearings need no annual servicing.
• Easy Service Access - Fully exposed refrigerant connec-
tions, and a single panel covering the electrical controls
make for easy servicing of the unit.
• Secured Service Valves - Secured re-usable service valves
are provided on both the liquid and vapor sweat connections
for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
• Agency Listed - U.L. and C.U.L. listed - approved for out-
door application. The unit is certified in accordance with the
Unitary Small Equipment certification program, which is
based on ARI Standard 210/240.
571921-UTG-A-0410

Advertisement

loading
Need help?

Need help?

Do you have a question about the GHGD18 and is the answer not in the manual?

Questions and answers

Summary of Contents for York GHGD18

  • Page 1 • Secured Service Valves - Secured re-usable service valves Visit us on the web at www.york.com are provided on both the liquid and vapor sweat connections Additional rating information can be found at for ease of evacuating and charging.
  • Page 2: Physical And Electrical Data

    571921-UTG-A-0410 Physical and Electrical Data GHGD18 GHGD24 GHGD30 GHGD36 GHGD42 GHGD48 GHGD60 MODEL S41S3 S41S4 S41S4 S41S4 S41S4 S41S4 S41S4 Unit Supply Voltage 208-230V, 1 60Hz 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 11.9 11.2 14.1 19.7 20.9 25.6...
  • Page 3 571921-UTG-A-0410 System Charge for Various Matched Systems Outdoor Unit GHGD18S41S3 GHGD24S41S4 GHGD30S41S4 GHGD36S41S4 GHGD42S41S4 GHGD48S41S4 GHGD60S41S4 .051/4F1 .054/4G1 .063/4G1 .071/4H1 .075/4H1 Required Orifice or TXV Factory Charge, lbs-oz 6 - 6 9 - 6 9 - 0 10 - 0 9 - 10 14 - 12 13 - 13...
  • Page 4 571921-UTG-A-0410 COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL SEER TOTAL SENS. 13 SEER HP WITH MA MA08B FC/MC18B 18.0 14.0 13.00 11.00 GHGD18S41S3 MA08B FC/MC24B 18.0 14.0 13.50 11.00 MA12B FC/MC35 23.6...
  • Page 5 571921-UTG-A-0410 COOLING CAPACITY - With Air Handler Coils (Continued) AIR HANDLER COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL SEER TOTAL SENS. 13 SEER HP WITH AHP / SHP / AHX / F*FP AHP18 – 18.0 14.0 13.00 11.00 AHX18 –...
  • Page 6 571921-UTG-A-0410 COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils FURNACE** COOLING COIL NET MBH UNIT MODEL CFM RANGE RATED MODEL SEER (Min.-max.) TOTAL SENS. 450 - 750 14,17 FC/MC/PC18 18.0 14.0 13.00 11.00 450 - 750 14,17 FC/MC/PC24 18.0 14.0 13.50...
  • Page 7 571921-UTG-A-0410 COOLING CAPACITY - With High Efficiency Motor Furnaces COOLING UNIT FURNACE COIL Net MBH RATED MODEL MODEL MODEL SEER TOTAL SENS. 13 SEER HP WITH VARIABLE SPEED FURNACES T*(8,L)X*A12 FC/MC/PC18A 18.0 14.3 14.00 12.00 T*(8,L)X*B12 FC/MC/PC18B 18.0 14.6 14.00 12.00 T*9X*B12 FC/MC/PC18B...
  • Page 8 571921-UTG-A-0410 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) COOLING UNIT FURNACE COIL Net MBH RATED MODEL MODEL MODEL SEER TOTAL SENS. 13 SEER HP WITH VARIABLE SPEED FURNACES (T*9C/T*9V)*C20 FC/MC/PC35C 24.0 17.2 14.50 12.00 (T*(8,L)C/T*8V)*A12 FC/MC/PC37A 24.0 17.3 14.50 12.00 (T*(8,L)C/T*8V)*B12...
  • Page 9 571921-UTG-A-0410 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) COOLING UNIT FURNACE COIL Net MBH RATED MODEL MODEL MODEL SEER TOTAL SENS. 13 SEER HP WITH VARIABLE SPEED FURNACES (T*(8,L)C/T*8V)*B12 FC/MC/PC43B 1270 36.0 27.2 13.75 11.50 (T*(8,L)C/T*8V)*C16 FC/MC/PC43C 1205 36.0 26.8 14.50...
  • Page 10 571921-UTG-A-0410 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) COOLING UNIT FURNACE COIL Net MBH RATED MODEL MODEL MODEL SEER TOTAL SENS. 13 SEER HP WITH VARIABLE SPEED FURNACES (T*(8,L)C/T*8V)*C16 UC60C 1420 41.0 31.4 13.75 11.50 (T*(8,L)C/T*8V)*C20 UC60C 1410 41.0 31.4 14.00...
  • Page 11 571921-UTG-A-0410 HEATING CAPACITY - With Air Handler ARI HEATING UNIT COIL 47F 17F HSPF MODEL* HANDLER MODEL 13 SEER HP WITH MA MA08B FC/MC18B 18.0 3.44 1.45 11.5 2.15 1.36 7.70 GHGD18S41S3 MA08B FC/MC24B 18.0 3.44 1.45 11.5 2.15 1.36 7.70 GHGD24S41S4 MA12B...
  • Page 12 571921-UTG-A-0410 HEATING CAPACITY - With Air Handler (Continued) ARI HEATING UNIT COIL 47F 17F HSPF MODEL* HANDLER MODEL 13 SEER HP WITH AHP / SHP / AHX / F*FP AHP18 – 18.0 3.38 1.47 2.16 1.11 7.70 AHX18 – 18.0 3.58 1.47 2.52...
  • Page 13 571921-UTG-A-0410 HEATING CAPACITY - Upflow, Downflow, and Horizontal Furnaces and Coils ARI HEATING UNIT COIL 47F 17F HSPF MODEL* MODEL FC/MC/PC/UC18 18.0 3.32 1.50 12.7 3.00 1.24 7.70 FC/MC/PC/UC24 18.0 3.44 1.45 10.4 2.60 1.17 7.70 GHGD18S41S3 HC18 18.0 3.32 1.50 12.7 3.00...
  • Page 14 571921-UTG-A-0410 HEATING CAPACITY - With High Efficiency Motor Furnaces ARI HEATING FURNACE COIL MODEL 47F 17F HSPF MODEL MODEL 13 SEER HP WITH VARIABLE SPEED FURNACES T*(8,L)X*A12 FC/MC/PC18A 18.0 2.92 1.81 11.1 2.24 1.45 8.10 T*(8,L)X*B12 FC/MC/PC18B 18.0 3.00 1.76 11.0 2.28 1.41...
  • Page 15 571921-UTG-A-0410 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) ARI HEATING FURNACE COIL MODEL 47F 17F HSPF MODEL MODEL Y*9C*C20 FC/MC/PC35C 23.0 3.52 1.91 13.1 2.54 1.51 8.15 (T*(8,L)C/T*8V)*A12 FC/MC/PC37A 23.8 3.62 1.93 13.6 2.54 1.57 8.20 (T*(8,L)C/T*8V)*B12 FC/MC/PC43B 23.4 3.60 1.90...
  • Page 16 571921-UTG-A-0410 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) ARI HEATING FURNACE COIL MODEL 47F 17F HSPF MODEL MODEL (T*(8,L)C/T*8V)*B12 FC/MC/PC43B 34.6 3.48 2.91 22.4 2.66 2.47 8.20 (T*(8,L)C/T*8V)*C16 FC/MC/PC43C 34.0 3.56 2.80 21.6 2.74 2.31 8.20 (T*(8,L)C/T*8V)*C20 FC/MC/PC43C 33.8 3.58 2.77...
  • Page 17 571921-UTG-A-0410 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) ARI HEATING FURNACE COIL MODEL 47F 17F HSPF MODEL MODEL (T*(8,L)C/T*8V)*C20 UC60C 39.5 3.88 2.98 22.2 2.62 2.48 8.20 Y*9C*C16 UC60C 40.0 3.74 3.13 22.8 2.52 2.65 8.20 GHGD42S41S4 Y*9C*C20 UC60C 40.0 3.78...
  • Page 18 571921-UTG-A-0410 ACCESSORIES Compressor Blanket - Designed to further reduce the normal operating sound. Refer to Price Manual for specific model numbers. Thermal Expansion Valve Kit - 1TVM4 Series TXV kit used if Start Assist Kit (2SA067*) - May be required on 24, 30, 36, & required.
  • Page 19: Typical Installation

    571921-UTG-A-0410 TYPICAL INSTALLATION MINIMUM 24” SERVICE ACCESS CLEARANCE THERMOSTAT 48” OVERHEAD ON ONE SIDE CLEARANCE WEATHERPROOF DISCONNECT SWITCH NEC CLASS 1 WIRING 10” CLEARANCE TO FURNACE OR AROUND PERIMETER AIR HANDLER TERMINAL BLOCK NEC CLASS 2 WIRING TO INDOOR COIL NOTE: ALL OUTDOOR WIRING CONTROL...
  • Page 20 571921-UTG-A-0410 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. GHGD18S41S3 INDOOR COIL MODEL NO. AHP18 IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 16.8 18.5 18.8 20.3 21.7 18.9 19.4 19.9 21.3 22.3 21.0 20.3 20.9 22.2 22.9 S.C.
  • Page 21 571921-UTG-A-0410 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. GHGD24S41S4 INDOOR COIL MODEL NO. AHP30 IDCFM 1000 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 22.6 25.9 25.9 28.3 29.4 25.2 27.1 26.8 29.2 30.4 27.9 28.3 27.6 30.0 31.4 S.C.
  • Page 22 571921-UTG-A-0410 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. GHGD30S41S4 INDOOR COIL MODEL NO. AHP30 IDCFM 1000 1200 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 29.1 31.3 31.4 34.3 36.1 31.0 32.7 32.8 35.2 36.6 33.0 34.1 34.1 36.1 37.2...
  • Page 23 571921-UTG-A-0410 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. GHGD36S41S4 INDOOR COIL MODEL NO. AHP36 IDCFM 1000 1200 1400 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 35.0 39.8 39.9 42.7 45.2 37.7 40.6 41.0 43.5 45.7 40.5 41.5 42.0 44.4...
  • Page 24 571921-UTG-A-0410 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. GHGD42S41S4 INDOOR COIL MODEL NO. AHP48 IDCFM 1200 1400 1600 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 42.5 44.2 45.0 49.4 52.7 44.4 45.8 46.4 50.5 53.5 46.4 47.4 47.7 51.5...
  • Page 25 571921-UTG-A-0410 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. GHGD48S41S4 INDOOR COIL MODEL NO. AHP48 IDCFM 1510 1710 1910 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 47.6 50.1 49.8 54.1 60.7 49.4 50.8 51.0 55.8 61.9 51.2 51.5 52.2 57.5...
  • Page 26 571921-UTG-A-0410 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. GHGD60S41S4 INDOOR COIL MODEL NO. AHX60 IDCFM 1630 1830 2030 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 54.6 57.9 58.1 63.9 69.9 56.8 59.2 59.2 65.2 71.2 58.9 60.5 60.3 66.5...
  • Page 27 571921-UTG-A-0410 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO GHGD18S41S3 EVAPORATOR COIL MODEL NO AHP18 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 21.1 22.2 23.3 20.5 21.6 22.6 19.9 20.9 21.9 18.6 19.2...
  • Page 28 571921-UTG-A-0410 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO GHGD24S41S4 EVAPORATOR COIL MODEL NO AHP30 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1000 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 27.2 26.5 25.7 26.4 25.9 25.4 25.6 25.3 25.0 24.0...
  • Page 29 571921-UTG-A-0410 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO GHGD30S41S4 EVAPORATOR COIL MODEL NO AHP30 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1000 1200 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 30.7 29.7 28.7 30.1 29.4 28.7 29.5 29.1 28.7...
  • Page 30 571921-UTG-A-0410 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO GHGD36S41S4 EVAPORATOR COIL MODEL NO AHP36 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1000 1200 1400 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 37.9 37.1 36.3 37.4 36.8 36.3 36.9 36.6...
  • Page 31 571921-UTG-A-0410 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO GHGD42S41S4 EVAPORATOR COIL MODEL NO AHP48 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1200 1400 1600 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 45.8 45.2 44.5 44.6 44.4 44.2 43.4 43.7...
  • Page 32 571921-UTG-A-0410 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO GHGD48S41S4 EVAPORATOR COIL MODEL NO AHP48 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1400 1600 1800 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 54.6 54.4 54.2 53.1 53.2 53.3 51.6 52.0...
  • Page 33 571921-UTG-A-0410 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO GHGD60S41S4 EVAPORATOR COIL MODEL NO AHX60 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1600 1800 2000 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 62.8 61.5 60.1 63.2 62.2 61.2 63.6 62.9...
  • Page 34 Subject to change without notice. Published in U.S.A. 571921-UTG-A-0410 Copyright © 2010 by Johnson Controls, Inc. All rights reserved. Supersedes: 556732-UTG-A-0210 Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069...