Available languages

Message
Meaning
EVU STOP
Indicates that the additional function EVU is active. This means that
the heat pump compressor and addition are off as long as EVU is
active.
NO DEMAND
Indicates that there is no heating production demand.
HEAT
HIGHPRESS
Alarm that indicates that the high pressure switch has deployed.
ERROR
LOWPRESS
Alarm that indicates that the low pressure switch has deployed.
ERROR
MOTOR P
Alarm that indicates that the motor protection has deployed.
ERROR
BRINEFLOW
Appears if the accessory flow switch is installed. Indicates that the
LOW
flow in the brine system is low.
SENSOR
Alarm that indicates a faulty sensor.
HEATPUMP
Indicates that the compressor will start within 30 seconds. The brine
START
pump has started.
HEATPUMP+
Indicates that heat production is active with both compressor and
ADD.HEAT
auxiliary heater.
START – -MIN
Indicates that there is a heating production demand and will start in
the specified number of minutes.
ADD. HEAT
Indicates that there is an auxiliary heater demand.
Text specific to Geysir Air
Appears with applicable heat pump operating status text.
Message
Meaning
DEFROST
Indicates the temperature for defrost.