1.0 Configure the DIP Switches

To use DIP-switch configuration, you must first set the DIP switches to a position other than all OFF or all ON
before powering-up the CopperLink. To configure your CL1314MDE using the DIP switches, refer to the section
entitled "Hardware (DIP-switch) configuration" in the CopperLink Model 1314MDE User Manual.
2.0 Power up the CL1314MDE
The CL1314MDE comes with either an external AC or external DC power supply.
2.1 Models with external AC adapter
To connect the AC power supply, determine the positive lead and negative lead on the power adapter. Insert the
positive lead into the opening on the terminal block labeled + and the negative lead into the opening on the ter-
minal block labeled -. Tighten the screws on the block to secure the wires. The CL1314MDE powers up as soon as
it is connected to an AC power source—there is no power switch.
2.2 Models with external DC power supply
The 36-60 VDC DC to DC adapter is supplied with the DC version of the CL1314MDE. The black and red leads on
one end of the power supply plug into a DC source (nominal 48VDC), and the leads on the other end connect to
the terminal block power connector on the CL1314MDE.
To Terminal Block
Power Connector
Black lead (-V)
Red lead (+V)
CopperLink Model 1314MDE Quick Start Guide
Power Supply Installation
Figure 1.
-Vin
+Vin
Figure 2.
DC Power Supply
To -48VDC
Source
-Vin
Black lead (-V)
Red lead (+V)
+Vin
3