8. Interface Specifications

8.1. RS-232C Interface

Settings and Communication

8.1.1.
Reading menu barcodes [ZZ] + [U2] + [ZZ] can set the RS-232C interface default.
Flow control time out
You can change the communication condition using the menu barcode.

Signal Level

8.1.2.
Signal Name
Item
Baud rate
Start/stop bits
Data bits
Parity bits
Handshaking
I/O
Mark/OFF
TxD
OUT
-5 to -15
RxD
IN
-3 to -15
RTS
OUT
-5 to -15
CTS
IN
-3 to -15
[U2] setting
9600 BPS
1 bit
8 bits
No parity
No handshake
Indefinitely
RS-232C Level (V)
Space/ON
+5 to +15
+3 to +15
+5 to +15
+3 to +15
18