Manual No. 25-ULPNR101-03; Feb, 2003
Scanner
27. Transmitting Error Indications (Trigger Enabled only)
Computer
Command
(Z7)
5E
5F
5G
5H
5I
5J
28. Print Quality Adjustments
Computer
Command
(Z7)
X4
X5
X6
X7
Function
/Description
START/END
Programming Menu
Do not transmit error code
Transmit "BR" <CR> for bad
read or no read
Transmit <STX>">"<ETX>
for bad read;
<STX>"?"<ETX> for no read
Transmit ">"<CR> for bad read
Transmit "?"<CR> for no read
Transmit "CAN"<CR> for bad
read or no read
Transmit <STX>"CAN"<ETX>
for bad read or no read
Function
/Description
START/END
Programming Menu
For lower density, poor print
quality bar code, e.g., dot matrix
with voids (low analog gain)
For high density, good print
quality bar code without voids
(high analog gain)
Output data obtained from Low
or High analog gain
Output data obtained from Low
and High analog gain
LPN5627 / LPR5627 Laser Fixed Mount
Bar Code
Command
-[8-
-6F-
-6G-
-6H-
-6I-
-6J-
-6K-
Bar Code
Command
-[8-
-Y5-
-Y6-
-Y7-
-Y8-