Fixing The Number Of Digits - Opticon LPN5627 User Manual

Miniature high speed laser fixed position scanner
Table of Contents

Advertisement

Manual No. 25-ULPNR101-03; Feb, 2003
Scanner

10. Fixing the Number of Digits

Computer
Command
(Z7)
7V
7W
(H0)
(H1)
(H4)
H2
H3
To avoid truncation errors, the scanner can be programmed to only decode bar codes of one specific
length, i.e., containing a specific number of digits. It is also possible to program the scanner to only
decode bar codes of either of two specific lengths.
To fix one (1) length (or number
of digits) of bar code:
1. Scan "START" to enter the
programming mode
2. Scan "Enable fixation(H1)" bar
code
3. Scan a sample bar code of
the desired length
4. Repeat Step #3, re-scanning
the sample bar code
5. Scan "STOP" to exit the
programming mode
NOTE: Fixation can also be programmed using computer commands through your RS232 by typing
<ESC>7V<CR> followed by <+>2 digit length 1<CR>. 7W would be appropriate for length 2.
Type<+>00<CR> to define either length as no fixed number.
"Fixing the Number of Digits" can only be applied to Code 39, Codabar (NW-7), 2 or 5 and MSI/Plessey.
WPC, Code 93, IATA and Code 128 are not affected.
Function
/Description
START/END
Programming Menu
Enable fixation
(1 Length)
Enable fixation
(2 Lengths)
Disable fixation
Enable fixation
(1 length)
Enable fixation
t
(
lengths)
Disable 1 character
Code 39 and Codabar (NW-7);
Disable 2 characters 2 of 5
Enable 1 character
Code 39 and Codabar (NW-7);
Enable 2 characters 2 of 5
LPN5627 / LPR5627 Laser Fixed Mount
Bar Code
Command
-[8-
-I1-
-I2-
-I5-
-I3-
-I!-
To fix two (2) different lengths
of bar codes:
1. Scan "START" to enter
the programming mode
2. Scan "Enable fixation(H4)" bar
code
3. Scan a sample bar code of
the desired length #1
4. Scan a sample bar code
of the desired length #2
5.
Scan "STOP" to exit the
programming mode
Page 37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lpr5627

Table of Contents