62
Multifeed alarm document out-sorting
NOTE: The Allow Maximum Length override will not disable
Controlled Dual Stacking Length Protection.
If your goal is to sort documents that
have triggered a multifeed alarm,
configure the Stacking settings as
follows:
Stack to put detected documents in:
2 (Stack #2),
and set the Detect Based On: Multifeed
option.
Triggering exception stacking by
multifeed can provide additional
functionality. For example, stacking
documents that trigger a multifeed alarm
in Stack #2 can be a way to sort thicker
documents that you cannot sort by size
or patch.
A-61849/ISIS January 2016