SAFETY
INFORMATION
Continued
14. Do not use heater if any part has
been under water. lmmediately call
a qualified service technician to in-
spect the room heater and to
p lac e an y p art o f t h e c o n t r o l
system, and any gas control which
has been under water.
15. Turn off and unplug heater and let
cool before servicing. Only a quali-
fied service person should service
and repair heater.
16. Operating heater above elevations
of 4,500 feet could cause pilot
outage.
17. Do not operate heater if any log is
broken. Do not operate heater if a
lo g is c hip p ed (d im e-sized o r
larger).
18. To prevent performance problems,
do not use fuel tank of less than
100 lbs. capacity.

PRODUCT FEATURES

SAFETY PILOT
This heater has a pilot with an
Oxygen Depletion Sensing (ODS) safety
shutoff system. The ODS/pilot is a re-
quired feature for vent-free room heaters.
The ODS/pilot shuts off the heater if there
is not enough fresh air.
State of Massachusetts:
must be made by a licensed plumber or gas
fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural gas-fired
supplemental room heaters shall provide to
each purchaser a
copy of 527 CMR 30 upon sale of the unit.
In the state of Massachusetts, unvented pro-
pane or nature gas-fired space heaters shall
be prohibited in bedrooms and bathrooms.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS
Water vapor is a by-product of gas combustion.An unvented
room heater productes approximately one (1) ounce (30ml)
of water for every 1,000 BTU's (.3KW's) of gas input per hour.
Unvented room heaters are recommended as supplemental
heat (a room) rather than a primary heat source (an entire
house) .In most supplemental heat application, the water
vapor does not create a problem. In most applications, the
water vapor enhances the low humidity at mosphere
experience during cold weather.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor.
This system requires no matches,
batteries, or other sources to light
heater.

LOCAL CODES

re-
lnstall and use heater with care.
Fol low all local codes. In the
absence of local codes, use the
latest edition of The National Fuel
Gas Code. ANSI Z223.1, also known
as NFPA54*.
*Available from:
American National Standards
lnstitute, lnc.
1430 Broadway
New York. NY10018
National Fire Protection
Association, lnc.
Batterymarch Park
Quincy. MA 02269
The installation
This heater is designed for vent-
free operation. State and local codes
in some areas prohibit the use of
vent-free heaters.
UNPACKING
1. Remove top inner pack.
2. Tilt carton so that fireplace is upright.
3. Remove protective side packaging.
4. Slide fireplace out of carton.
5. Remove protective plastic wrap.
6. Remove screen by lifting and then
7. Remove log set by cutting plastic
8. Carefully unwrap logs.
9. Check for any shipping damage. If

PRODUCT IDENTIFICATION

Figure1-Compact Vent-Free Fireplace
The following steps will help insure that water vapor does
not become a problem.
1. Be sure the heater is sized properly for the application,
including ample combusion air and circulation air.
2. If high humidity is experienced, a dehumidifier may be
used to help lower the water vapor content of the air.
3. Do not use an unvented room heater as the primary
heat source.
3
2
pulling forward.
ties.
fireplace or logs are damaged,
promptly inform dealer where you
bought the fireplace from.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents