ACCESSORY NFHTX186
Tools required: Philips screwdriver
NOTICE: Shut off gas heater dur-
i n g t h e f o l l o w i n g b l o w e r
installation.
1.From back of heater remove the knock
out center panel with two brackets at the
four sides with a Philips head screwdriver
(see Figure 1).
2. Attach the two brackets to blower hous
ing using four white screws provided in
blower kit (2 for each bracket) (see Fig
ure 2). Tighten screws securely. Then
guide the green grounding means wire
and downlead of motor through the panel
capped hole.
3. Guide the four strand wire of downlead
through the panel hole. Connect the two
yellow leads and the temperature control
switch on the temperature controlled
bracket togther. Secure the temperature
controlled bracket on the reflective panel
of firebox using two self-tapping screws
(See Figure 3-A).
4. Using the previously removed screws,
mount blower assembly to stove by reat
taching the knock-out center panel to rear
panel. Draw the four strand cable back-
Figure 1 Removing Knock-out Panel

INSTALLING BLOWER ACCESSORY

BLOWER ACCESSORY MODEL NFHTX186
ward so as to expose the three black,
green, white lines on the four strand
cable at the back of rear panel.Be sure
not to drop the temperature controlled
wire off the reflective panel. Connect the
green grounding means wire and four
strand cable together.Connect the two
black motor downleads respectively
and the remaining two black and white
wires together by the same means (see
Figure 3-A). (Note: the three wires
must be connected at the rear panel)
5. Using the thread that previously bond
the electrical wire to collect and pack
the outside connection wire of the
cable.
6. A . EN(L)250TYLA model Guide the
operating control housing through the
bottom hole of rear panel, and place
it on the mounting bracket in the door.
Mounting operating control housing to
the mounting bracket with two screw.
(see figure 4)
B. EN(L)250TYLBmodel Insert opera-
tion control housing at the back bot-
tom of stove.Use two black screws
provided in blower kit. Mount blower
operation control housing to the
bracket at the bottom of stove (see Fig
ure 5).
7.
Check to make sure that the power
cord is completely clear of blower
wheel and there are no foreign objects
in blower wheel.
P
Figure 2 Attaching Brackets To Blower
21
2 2
8. Use screws provided in blower
kit to as semble the plate which
assembled with strain relief
bushing and power cord on the
knock-out center panel.
9.Peel off the backing paper and
stick the supplied wiring diagram
decal on the back panel as show
in Figure 4-B.
10.Plug power cord into a conve
nient 3-prong grounded wall
recep tacle near the stove.
WARNING: 1. ELECTRICAL
GROUNDING INSTRUCTIONS:
This appliance is equipped
with a three-prong (grounding)
pl ug fo r you r p ro tec ti on
against shock hazard and
should be plugged directly into
a properly grounded three-
prong receptacle.
2. Do not let the wires touch
the reflective panel of the
firebox. Feed the wires of the
motor and green wire through
the hole of the knock-out
panel.
11. Using Auto/O/man switch. Turn
b lo wer o n an d c h ec k f o r
operation. Turn on Auto/O/Man
switch to the desired position.
Man position will remain con-
stantly on. Auto position will be
controlled by the thermostat on
fan blower unit. To stop the
operation, turn unit switch to the
O position.
12. A l l re m ain in g p art s f r o m
blower kit may be discarded.