Preparing for Operation and Monitoring
D Procedure for Setting the Parameter Write-prohibit Selection/Parameter
Initialization (n01)
Key sequence
Indicators
In approximately
1 s.
H Reading Parameter Settings (rEd)
The parameter settings saved in the Inverter can be read to the memory of the Digital Operator by set-
ting the Parameter Copy and Verify Function (n76) to "rEd."
D Procedure for Reading Parameter Settings
Key sequence
Indicators
(After
completion)
or
Display
example
Power ON
Press the Mode Key until the PRGM indicator lights.
Check that n01 is shown on the data display.
Press the Enter Key. The setting for the specified
parameter will be displayed.
Press the Increment Key to display 1. (The display will
flash.)
Press the Enter Key to enter the setting. The display
will stop flashing.
The parameter number will be displayed.
Display
example
Check that PRGM is lit. (Press the Mode Key if any
other indicator is lit.)
Use the Increment or Decrement Key to display n76.
Press the Enter Key. "rdy" will flash.
Press the Increment Key to display "rEd".
Press the Enter Key. The Inverter parameters will be
read to the memory in the Digital Operator. During this
time, the display will flash.
When reading has been completed, "End" will be
displayed.
Press the Mode Key or the Enter Key to return to the
parameter number display.
Chapter 3
Explanation
Explanation
3-13