List of Parameters
Parame-
Name
ter No.
(Register
No.
(Hex))
n01
Parameter
Used to prohibit parameters to be written, sets
write-pro-
parameters, or change the monitor range of
(0101)
hibit selec-
parameters.
tion/
Used to initialize parameters to default values.
parameter
initializa-
0: Sets or monitors parameter n01. Parame-
tion
1: Sets or monitors parameters n01 through
5: Enables continuous operation. (Parameters
6: Clears the error log.
8: Initializes parameters to default values in
9: Initializes parameters to default values in
Note
n02
Operation
Used to select the input method for the RUN
command
and STOP commands in remote mode.
(0102)
selection
0: The RUN and STOP/RESET Keys on the
1: Multi-function inputs through the control cir-
2: Operation commands via RS-422/485 com-
Note
n03
Frequency
Used to set the input method for the frequency
reference
reference in remote mode.
(0103)
selection
0: Digital Operator
1: Frequency reference 1 (n21)
2: Frequency reference control circuit terminal
3: Frequency reference control circuit terminal
4: Frequency reference control circuit terminal
6: Frequency reference via RS-422/485 com-
n04
Interrup-
Used to set the stopping method for use when
tion mode
the STOP command is input.
(0104)
selection
0: Decelerates to stop in preset time.
1: Coasts to stop (with output shut off by the
n05
Reverse
Used to select the operation with the reverse
rotation-
command input.
(0105)
prohibit
0: Reverse enabled.
selection
1: Reverse disabled.
10-2
Description
ters n02 through n79 can be monitored
only.
n79.
n01 to n79 can be set or monitored.)
2-wire sequence.
3-wire sequence.
With settings 0 or 1, operation com-
mands are ignored in Program Mode.
(Refer to 3-1-2 Drive Mode and Pro-
gram Mode.) Normally, use a setting of
0 or 1.
Digital Operator are enabled.
cuit terminals in 2- or 3-wire sequence.
munications are enabled.
The RUN command only through key
sequences on the Digital Operator is
acceptable in local mode.
(0 to 10 V)
(4 to 20 mA)
(0 to 20 mA)
munications
STOP command)
Setting
Unit of
Default
range
setting
setting
0, 1, 6, 8,
1
1
9
0 to 2
1
0
0 to 4, 6
1
0
0, 1
1
0
0, 1
1
0
Chapter 10
Changes
Refer-
during op-
ence
eration
page
No
5-2
No
5-7
No
5-8
No
5-17
No
5-16