Omron SYSDRIVE 3G3JV User Manual page 228

Compact simplified inverters
Hide thumbs Also See for SYSDRIVE 3G3JV:
Table of Contents

Advertisement

List of Parameters
Parame-
Name
ter No.
(Register
No.
(Hex))
n06
STOP/RE-
Used to select the stop method in remote
SET Key
mode with n02 for operation mode selection
(0106)
function
set to 1.
selection
0: STOP/RESET Key of the Digital Operator
1: STOP/RESET Key of the Digital Operator
n07
Frequency
Used to set the input method for the frequency
selection
reference in local mode.
(0107)
in local
0: The FREQ adjuster of the Digital Operator
mode
1: Key sequences on the Digital Operator
n08
Key se-
Used to enable the Enter Key for setting the
quential
frequency reference with the Increment and
(0108)
frequency
Decrement Keys.
setting
0: The value is entered with the Enter Key
1: The value is enabled when the value is
n09
Maximum
Used to set the V/f pattern as the basic char-
frequency
acteristic of the Inverter with output voltage
(0109)
(FMAX)
per frequency set.
Output
n10
Maximum
voltage
voltage
(010A)
(VMAX)
n11
Maximum
voltage
(010B)
frequency
(FA)
n12
Middle
output fre-
(010C)
quency
Note
(FB)
n13
Middle
output fre-
(010D)
quency
Note
voltage
(VC)
n14
Minimum
output fre-
(010E)
quency
(FMIN)
n15
Minimum
output fre-
(010F)
quency
voltage
(VMIN)
n16
Accelera-
Acceleration time: The time required to go
from 0% to 100% of the maximum frequency.
tion time 1
(0110)
Deceleration time: The time required to go
Deceleration time: The time required to go
n17
Decelera-
from 100% to 0% of the maximum frequency.
tion time 1
(0111)
Note
n18
Accelera-
tion time 2
(0112)
n19
Decelera-
tion time 2
(0113)
Description
enabled.
disabled.
enabled.
enabled.
pressed.
input.
Set the parameters so that the follow-
ing condition will be satisfied.
ing condition will be satisfied
n14 x n12 < n11 x n09
The value set in n13 will be ignored if
parameters n14 and n12 are the same
in value.
i
l
The actual acceleration or deceleration
time is obtained from the following for-
time is obtained from the following for
mula.
Acceleration/Deceleration time = (Ac-
celeration/Deceleration time set value)
l
ti
/D
l
ti
ti
× (Frequency reference value) ÷ (Max.
frequency)
Setting
Unit of
range
setting
0, 1
1
0, 1
1
0, 1
1
50.0 to
0.1 Hz
400
(see note
1)
1 to 255
1 V
(see note
2)
0.2 to 400 0.1 Hz
(see note
1)
Frequency
Frequency
0.1 to 399 0.1 Hz
(Hz)
(see note
1)
1 to 255
1 V
(see note
2)
0.1 to
0.1 Hz
10.0
1 to 50
1 V
(see note
2)
0.0 to 999 0.1 s
t
l
)
Chapter 10
Default
Changes
Refer-
setting
during op-
ence
eration
page
0
No
5-7
0
No
5-8
0
No
5-12
60.0
No
5-4
200 (see
No
5-4
note 2)
60.0
No
5-4
1.5
No
5-4
12 (see
No
5-4
note 2)
1.5
No
5-4
12.0 (see
No
5-4
note 2)
10.0
Yes
5-14
10.0
Yes
5-14
10.0
Yes
5-14
10.0
Yes
5-14
10-3