Basic Operation
Value
Function
10
Inching frequency
command
11
Acceleration/Deceleration
time selection
12
External base block
command (NO)
13
External base block
command (NC)
14
Search command
(Searching starts from
maximum frequency)
15
Search command
(Searching starts from
preset frequency)
16
Acceleration/Decelera-
tion-prohibit command
17
Local or remote selection
18
Communications or
remote selection
19
Emergency stop fault
(NO)
20
Emergency stop alarm
(NO)
21
Emergency stop fault
(NC)
22
Emergency stop alarm
(NC)
34
Up or down command
35
Self-diagnostic test
ON: Inching frequency command (taking precedence over the
multi-step speed reference)
ON: Acceleration time 2 and deceleration time 2 are selected.
ON: Output shut off (while motor coasting to a stop and "bb"
flashing)
OFF: Output shut off (with motor free running and "bb" flashing)
ON: Speed search (Searching starts from n09)
ON: Speed search
ON: Acceleration/Deceleration is on hold (running at parameter
frequency)
ON: Local mode (operated with the Digital Operator)
Note After this setting is made, mode selection with the Digital Oper-
ator is not possible.
ON: RS-422/485 communications input is enabled.
OFF: The settings of n02 and n03 are enabled.
The Inverter stops according to the setting in n04 for interruption
mode selection with the emergency stop input turned ON.
n04 set to 0: Decelerates to stop at deceleration time 2 set in
n04 set to 0: Decelerates to stop at deceleration time 2 set in
n19. n04 set to 1: Coasts to a stop.
Note NO: Emergency stop with the contact closed.
g
y
NC: Emergency stop with the contact opened.
Note Fault: Fault output is ON and reset with RESET input. Alarm
output is ON (no reset required).
output is ON (no reset required)
Note "STP" is displayed (lit with fault input ON and flashes with alarm
input ON)
Up or down command (set in n39 only)
By setting n39 to 34, the set value in n38 is ignored and the
following settings are forcibly made.
S4: Up command
Note It is impossible to set the up or down command and multi-step
speed references 1 through 3 together.
Note For up and down command functions in detail, refer to 6-7-7
UP/DOWN Command Frequency Memory (n62).
ON: RS-422/485 communications self-diagnostic test (set in n39
only)
Description
p
S5: Down command
Chapter 5
5-19