Chapter 4 Parameter Index
Function
Function Name
code
Input phase loss
Pd.09
detection delay
time
Output phase loss
detection level
(SP0)
(Motor rated
current
Pd.10
corresponds to
100%)
Reserved
(S2R4GB,
S2R75GB)
Output phase loss
Pd.11
detection delay
time
Enabling
Pd.12
keyboard keys
UP/DN
AE1, AE2 Alarm
Pd.13
choice
Pd.14
Auto reset times
Pd.15
Reset Interval
Increase and
decrease of
Pd.16
over-current
counting
Automatic
Pd.17
running selection
after power on
Running selection
Pd.18
after power off
Resistance
coefficient to
impact load
Pd.19
Reserved(3004G/
35R5PB or
below)
76
Range of settings
2~255s
0~100%
0.0~25.0s
0: Invalid
1: Enabled
0: Not show alarm
1: Display alarm
0~10,"0"means "auto reset" is
disabled.
Only 3 faults have auto reset function
2.0~20.0s /per time
0 ~ 250
0:No action
1:Run automatically
0:Machine shut down (through the
shutdown way)
1:Don't stop(short time)
100.0~250.0%
MODBUS
Default
Change
Address
10s
×
2%
×
2.0s
×
0
×
0
×
0
×
5.0s
×
100
×
1
×
1
×
This
value
depends
×
on the
inverte
r model
0E09
0E0A
0E0B
0E0C
0E0D
0E0E
0E0F
0E10
0E11
0E12
0E13