Function
Parameter
code
name
Feed
P7.00
select
Feedback
P7.01
select
MODBUS
Pb.00
Baud rate
selection
MODBUS
Pb.01
Station
Address
MODBUS
Pb.02
Parity
Communi
Pb.03
cation
overtime
check
Response
Pb.04
delay time
Communi
cation
Pb.05
frequency
instruction
unit
Setting range
0: PID feed
1: AI1 Terminal
2: AI2 Terminal
3: Pulse
4: Serial communication
0: AI1 Terminal
1: AI2 Terminal
2: Serial communication
3: Pulse feedback
4: |AI1-AI2|
5: Reserved
6: AI1+AI2
7: MIN{ AI1, AI2}
8: MAX{ AI1, AI2}
9: PG or single phase
speed measure input
0:1200
1:2400
2:4800
3:9600
4:19200
5:38400
* NOTE 2
0~31
* NOTE 3
0: Even parity
1: Odd parity
2: No parity * NOTE 2
0~100.0s
0: no overtime checking;
Other: timeout detection
time
0-500 ms
0:0.01 Hz * NOTE 4
1:0.1 Hz
Appendix 4 MODBUS Communication
Default Change
1
×
1
×
3
×
1
×
0
×
0.0s
5 ms
×
0
×
MODBUS
address
0004H
Given PID,
0~1000 is
corresponding
0.0~100.0%
0003H
communication
PID feedback,
0~1000 is
corresponding
0.0~100.0%