Fault
Fault categories
code
Over current in constant speed
OC3
Operation
Ou2
Over Voltage in Dec process
GF
Ground Fault
OL1
Motor Overload
SC
Load Short-Circuit
EF1
External Fault of terminal
Output phase failure or
SPO
Unbalance
Control circuit fault 2:
Transmission between the
inverter and keyboard is
CCF2
established once after
supplying power, but later
transmission fault continues
for more than 2 seconds.
CCF4
AD Conversion Fault
CCF6
CPU disturbance
HE
Hall current detection fault
PE.05 Running status at last fault
0: StP Stop
2: dEc Decelerate
PE.06 Fault History 1 (Last One)
PE.07 Fault History 2
PE.08 Fault History 3
Note:
Memorize the types of the last 3 faults. See Table 5-14-1 for the details of faults.
PE.09 Total Operating time
PE.10 Total Power On time
Chapter 5 Parameter Introductions
Fault
Fault categories
code
Ou1
Over Voltage in Acc process
Over voltage in constant speed
Ou3
operation
OH1
Heat-sink Overheat
OL2
Inverter Overload
External Fault of serial
EFO
communication
SP1
Input phase failure or Unbalance
Control Circuit Fault 1:
Transmission between the inverter
CCF1
and keyboard cannot be
established 5 seconds after
supplying power.
CCF3
EEPROM Fault
CCF5
RAM Fault
PCE
Parameters copy Error
dE
Pulse coder fault
Range: 0~3【StP】
1: Acc Accelerate
3: con constant
Range: Table 5-14-1【NULL】
Range: Table 5-14-1【NULL】
Range: Table 5-14-1【NULL】
Range: 0~65530h【0】
Range: 0~65530h【0】
159