Alpha 6000 User Manual page 68

Table of Contents

Advertisement

Function
Function Name
code
Physical value 3
corresponding to
P4.14
Max pulse value
Input
Pulse input filter
time constant 3
P4.15
(pulse Input
Terminal)
P4.16
PG Pulse Range
AO1 function
P4.17
definition
Reserved
(3004GB/35R5PB
or below)
P4.18
AO2 function
definition
(35R5GB/37R5PB
and above)
P4.19
DO output
AO1 output range
P4.20
selection
Reserved
(3004GB/ 35R5PB
or below)
P4.21
AO2 output range
selection(35R5GB
/37R5PB and
above)
P4.22
Gain of AO1
Reserved
(3004GB/ 35R5PB
or below)
P4.23
Gain of AO2
(35R5GB/37R5PB
and above)
Max output
P4.24
impulse frequency
of DO
Range of settings
0.0~100.0%
0.01~50.00s
1~9999
0: Output frequency before
compensation (0~ Maximum
Frequency)
1: Output current (0~2* inverter rated
current)
2: Output voltage (0~Maximum
Voltage)
3: PID feed (0~10V)
4: PID feedback (0~10V)
5: Adjust signals (5V)
6: Output torque (0~2*inverter rated
torque)
7: Output power (0~2*Inverter rated
power)
8: Bus voltage (0~1000V)
9: AI1 (0~10V)
10: AI2 (0~10V/0~20mA)
11: Output frequency after
compensation (0~Maximum
Frequency)
12~14: Reserved
15: NULL
0: 0~10V/0~20mA
1: 2~10V/4~20mA
Reserved
0: 0~10V/0~20mA
1: 2~10V/4~20mA
1~200%
Reserved
1~200%
Min Pulse frequency output of
DO~50.00kHz
Chapter 4 Parameter Index
MODBUS
Default
Change
Address
100.0%
0.05s
1024
0
×
0
-
1
×
15
×
0
0
-
0
100%
0
-
100%
10.00kH
z
050E
050F
0510
0511
0512
0513
0514
0515
0516
0517
0518
67