2.
Connect a DC power supply to the module test jig with a power cable.
Note:
Turn off the DC power supply at this stage.
3.
Set the DC supply voltage to 4.2 V.
4.
Set the jumper connector on the test jig to the bypass position.
5.
Set the phone mode switch to LOCAL position.
6.
Place the phone module to the test jig.
7.
Turn on the DC power supply, and wait for the LED jig to turn on.
8.
Start Phoenix service software on your PC.
Note:
Make sure that the Phoenix service software version on your computer is not older than
version of week 8 of 2008.
9.
Initialize Phoenix connection to the phone.
10. Choose File→Scan Product . Phone should be powered up in the LOCAL mode.
11. Once the Phoenix identifies the phone's product information, follow the WLAN front-end
troubleshooting procedure as shown in the flowchart below.
Page 4 –24
COMPANY CONFIDENTIAL
Copyright © 2008 Nokia. All rights reserved.
RM-247
RF troubleshooting
Issue 1