Epson Stylus NX510/515/SX510W/515W/TX550W/NX415/SX410/415/TX410/419/NX215/SX210/215/TX210/213/219/ME OFFICE 510
NX510/SX210 series only:
When installing the PF Encoder Sensor, be sure to attach the
acetate tape (x1) referring to the figure below.
Figure 4-65. Acetate Tape Position
DISASSEMBLY/ASSEMBLY
Align here with edge of
the PF Encoder Sensor
30mm
Disassembling the Printer Mechanism

4.5.10 PF Scale

Parts/Components need to be removed in advance
Document Cover/ASF Cover/Scanner Unit/Panel Unit/Upper Housing/Card Slot
Cover/Lower Housing/Main Board Unit/Left Frame/PF Encoder Sensor
Removal procedure
Pay attention to the following instructions.
C A U T I O N
Do not touch the PF Scale with bare hand.
Do not damage the PF Scale.
1.
Peel of the PF Scale that is secured with the double-sided tape (x1) from the
Spur Gear 32.4.
Spur Gear 32.4
Figure 4-66. Removing the PF Scale
Revision A
PF Scale
Double-sided Tape
124