EPSON Stylus C110/C120/D120

4.5.9 PF Scale

Part/Unit that should be removed before removing PF Scale
Upper Housing/Lower Housing/Main Board Unit/Left Frame/Panel Unit/PF
Encoder Sensor
Removal Procedure
Pay attention to the following instructions.
C A U T I O N
Do not touch the PF Scale with bare hand.
Do not damage the PF Scale.
1.
Peel of the PF Scale that is secured with the double-sided tape (x1) from the Spur
Gear 32.4.
Spur Gear 32.4
Figure 4-47. Removing PF Scale
DISASSEMBLY/ASSEMBLY
Downloaded from
www.Manualslib.com
PF Scale
Double-sided Tape
Disassembling Printer Mechanism
manuals search engine

4.5.10 PF Motor

Part/Unit that should be removed before removing PF Motor
Upper Housing/Lower Housing/Main Board Unit/Left Frame/Panel Unit/PF
Encoder Sensor/PF Scale
Removal Procedure
1.
Release the PF Motor connector cable from the notches (x2) of the Base Frame.
Notch
Figure 4-48. Removing PF Motor (1)
2.
Remove the Grounding Spring from the PF Motor.
3.
Remove the screws (x3) that secure the PF Motor, and remove it.
Grounding Spring
PF Motor
2
Figure 4-49. Removing PF Motor (2)
Revision B
PF Motor Connector Cable
3
1
Guide Pin and Positioning Hole
C.B.S. 3x6, F/Zn-3C (8±1kgfcm)
C.B.P. 3x8, F/Zn-3C (6±1kgfcm)