4.4 HEATSCOPE™ ceiling suspension 2 x 45° MHS-DAHDOP
· The image shows two HEATSCOPE™ radiant heaters with the 11,81 Inch / 300mm ceiling suspension
MHS-DAH 300 plus additional 45° dual ceiling suspension (fixing bracket) MHS-DAHDOP.
· Fit the oval ceiling attachment MHS-DAHDB, which comes as an accessory, on/to the intended installati-
on surface. (Please note the minimum clearance for installation surfaces in Section 6.)
· Fit two mounting brackets MHS-MH for each 45° dual fixing bracket MHS-DAHDOP using one of the
supplied screws and washers – in the following sequence: screw, washer, mounting bracket, dual fixing
bracket. Make sure that the securing clips on the mounting brackets are oppositely aligned to each
other and are facing outward.
· Now connect the ceiling suspension MHS-DAH with the dual fixing brackets MHS-DAHDOP and the
oval ceiling attachment MHS-DAHDB as follows: Screw the threaded element to the dual fixing bracket
using the screw supplied. Then secure the extension tube to the threaded element with the dual ceiling
suspension. Screw the whole assembly into the oval ceiling attachment, which you already fitted on/to
the designated installation surface.
· Repeat these steps with the second dual mounting bracket MHS-DAHDOP. Make sure that both
mounting bracket pairs are mounted exactly in series one after the other and that the securing clips are
oppositely aligned to each other and are facing outward.
· Finally slide the two HEATSCOPE™ radiant heaters onto the mounting brackets until the clip clicks
audibly into place on both sides above the raised side plate and the HEATSCOPE™ heaters are secured
from slipping out.