Electric ambient carbon radiant heater for indoor and outdoor areas

Advertisement

Quick Links

ambient heating | made in Germany
ORIGINAL INSTALLATION AND INSTRUCTION MANUAL
Electric ambient carbon radiant heater for
indoor and outdoor areas
C B
S C H E M E
IP44
IP24
VISION
SPOT
Made in Germany
AU
WEEE-Reg.-Nr.
D E 4 5 6 5 0 4 4 1

Advertisement

Table of Contents
loading

Summary of Contents for Heatscope MHS-SM1600

  • Page 1 ambient heating | made in Germany ORIGINAL INSTALLATION AND INSTRUCTION MANUAL Electric ambient carbon radiant heater for indoor and outdoor areas IP44 IP24 VISION SPOT S C H E M E Made in Germany WEEE-Reg.-Nr. D E 4 5 6 5 0 4 4 1...
  • Page 2: Safety Information

    The unit should be labelled accordingly to prevent it being reconnected. 2. For installation use only the supplied accessories or original accessories approved by the manufacturer. The power cable or other components of the HEATSCOPE radiant heater may ®...
  • Page 3 HEATSCOPE during operation and up to 30 minutes after switching it off. ® 6. For your own safety, never dry textiles or other materials using the HEATSCOPE . Covering the ® radiant heater may result in a fire! Always maintain a distance from the heating surface of the HEATSCOPE of at least 150 cm from textiles, cloth and other easy inflammable soft materials.
  • Page 4 M U N I C H H O M E S Y S T E M S 11. The power cable or buried cable with omnipolar switch may only be replaced by a professi- onal specialist electrical company enlisted or approved by the manufacturer. Heating elements, other components or parts of the housing may only be replaced by a service organisation enlisted by the manufacturer.
  • Page 5 A M B I E N T H E A T I N G S O L U T I O N S the unit must be at least 20 cm from the nearest power source. Sockets/power sources must be freely accessible at all times and comply with the following specifications: 220–240 V AC ~, 50/60 Hz, 16 A with 16 A fuse.
  • Page 6: Ceiling Installation

    M U N I C H H O M E S Y S T E M S CeilinG inStAllAtion 110cm  max. A min. B min. B mHS-Sm1600/mHS-SP1600 max. 240 mm min. 135 mm mHS-Vt1600/mHS-Ve1600 max. 300 mm min. 175 mm mHS-Sm2200/mHS-SP2200 max.
  • Page 7: Wall Mounting

    A M B I E N T H E A T I N G S O L U T I O N S WAll moUntinG 110cm  max. A min. B min. B   max. A max. A min. B min.
  • Page 8: Manual Control

    M U N I C H H O M E S Y S T E M S mAnUAl Control leD: MHS-SM1600, MHS-SM2200, MHS-SM2800 MHS-VE1600, MHS-VE2200, MHS-VE3200 100 % 50 % ir remote Control leD: MHS-SP1600, MHS-SP2200, MHS-SP2800 MHS-VT1600, MHS-VT2200, MHS-VT3200 ...
  • Page 9 A M B I E N T H E A T I N G S O L U T I O N S HeAtSCoPe ViSion and SPot – Wiring / Connecting regulation ® Pillar terminal 1000 K / 3 + 4 mDS Ht 0,5–6 mm², 3 + 4 pol.: (1) Wire protection with pin-in-hole protection for stripped litz wires and litz wires with cable end sleeves, (2) Tighten screws with 0.5 Nm, (3) Wiring / Connection Version 2, shortened litz...
  • Page 10 ConneCtion 220–240 V AC MHS-SP1600AB.400, MHS-SP2200AB.400, MHS-SP2800AB.400, MHS-SP1600BK.400, MHS-SP2200BK.400, MHS-SP2800BK.400, MHS-SP1600WT.400, MHS-SP2200WT.400, MHS-SP2800WT.400 MHS-VT1600AB.400, MHS-VT2200AB.400, MHS-VT3200AB.400, MHS-VT1600BK.400, MHS-VT2200BK.400, MHS-VT3200BK.400, HeAtSCoPe SP // HeAtSCoPe ® ® MHS-VT1600WT.400, MHS-VT2200WT.400, MHS-VT3200WT.400 220-240 V AC 50/60 Hz i n P U t Circuit breaker / fuse switch...
  • Page 11 A M B I E N T H E A T I N G S O L U T I O N S MHS-SM1600AB.400, MHS-SM2200AB.400, MHS-SM2800AB.400, MHS-SM1600BK.400, MHS-SM2200BK.400, MHS-SM2800BK.400, MHS-SM1600WT.400, MHS-SM2200WT.400, MHS-SM2800WT.400 MHS-VE1600AB.400, MHS-VE2200AB.400, MHS-VE3200AB.400, MHS-VE1600BK.400, MHS-VE2200BK.400, MHS-VE3200BK.400, HeAtSCoPe SP // HeAtSCoPe ® ® MHS-VE1600WT.400, MHS-VE2200WT.400, MHS-VE3200WT.400 220-240 V AC 50/60 Hz i n P U t...
  • Page 12 M U N I C H H O M E S Y S T E M S minimum distances wall mounting The following installation regulations ensure that the HEATSCOPE ambient heater is working effectively. ® All minimum clearances that must be met regardless of the installation environment are listed.
  • Page 13 A M B I E N T H E A T I N G S O L U T I O N S The clearances given are minimum values and may differ from the local building and fire regulations. The latter must be observed and complied with in any case. Tel.: +61 2 9997 3050 ·...
  • Page 14 M U N I C H H O M E S Y S T E M S minimum distances ceiling mounting The following installation regulations ensure that the HEATSCOPE ambient heater is working effectively. ® All minimum clearances that must be met regardless of the installation environment are listed.
  • Page 15 A M B I E N T H E A T I N G S O L U T I O N S The clearances given are minimum values and may differ from the local building and fire regulations. The latter must be observed and complied with in any case. Tel.: +61 2 9997 3050 ·...
  • Page 16 M U N I C H H O M E S Y S T E M S minimum distances for installation in glasshouses / conservatories The following installation regulations ensure that the HEATSCOPE ambient heater is working effectively. ® All minimum clearances that must be met regardless of the installation environment are listed.
  • Page 17 A M B I E N T H E A T I N G S O L U T I O N S The clearances given are minimum values and may differ from the local building and fire regulations. The latter must be observed and complied with in any case. >...
  • Page 18: Installation Instructions

    Unpacking the unit / packaging Unpack the unit and the accessories carefully. When opening the packaging, do not use sharp objects that could damage the unit. This product comes supplied in environmentally friendly packaging. All HEATSCOPE packaging that ® comes into circulation either directly or via the trade is certified in accordance with §6 of the German Packaging Directive.
  • Page 19 All cables must be positioned so that they cannot come into contact with the radiant heater at any time. The radiant heater must not be installed directly below a power socket. The sides of the HEATSCOPE ®...
  • Page 20 The unit must be disposed of professionally and in an environmentally friendly manner. The relevant legal regulations must be observed. Guarantee and warranty The HEATSCOPE is guaranteed for 24 months. The warranty period begins on the date on which the new ®...
  • Page 21 A M B I E N T H E A T I N G S O L U T I O N S models HeAtSCoPe SPot – manual control, 4 core cable ® SPECIFICATIONS: ON/OFF + 2 manually switchable power levels (100% or 50%) MHS-SM1600BK.400, MHS-SM2200BK.400, MHS-SM2800BK.400...
  • Page 22: Dimensions And Specifications

    ON/OFF + 100%, 50% ON/OFF + 100%, 50% DimenSionS & SPeCifiCAtionS Art.-no. Power Weight Sizes mHS-Sm1600 / mHS-SP1600 1600 W 4.0 kg 670 x 184 x 78 mm mHS-Sm2200 / mHS-SP2200 2200 W 4.5 kg 810 x 184 x 78 mm...
  • Page 23 ® EN / IEC 60335-1 and EN / IEC 60335-2-30 (Household and similar electrical appliances Safety) installation: Installation of heaters must be done acc. to installation guideline of the ORIGINAL HEATSCOPE INSTALLATION AND ® INSTRUCTION MANUAL. Min. distance between the two mounting brackets on back of the heater as designated, min.
  • Page 24 CoUntrieS USA, CAnADA, nortH AmeriCA frAnCe Denmark, Sweden, norway, finland, iceland mAD Design USA SArl HeAtSCoPe frAnCe Scandinavia Heatscope ApS 5875 Green Valley Circle, Suite 100 ZI Les gresses Sønder Klintvej 31 Culver City, CA 90230 USA 26290 Donzère FRANCE...

Table of Contents