ambient heating | made in Germany
ORIGINAL INSTALLATION AND INSTRUCTION MANUAL
Electric ambient carbon radiant heater for
indoor and outdoor areas
developed
designed
made in
Germany
IP24
EMC
US
E114556
Electrical Safety

Advertisement

loading

Summary of Contents for Heatscope SPOT MHS-SM Series

  • Page 1 ambient heating | made in Germany ORIGINAL INSTALLATION AND INSTRUCTION MANUAL Electric ambient carbon radiant heater for indoor and outdoor areas IP24 developed designed made in Germany E114556 Electrical Safety...
  • Page 2 M U N I C H H O M E S Y S T E M S Safety information HeatSCoPe infrared heaters must be installed and executed only by an authorized expert / ® trained professional electrician in accordance with the applicable standards and regulations for electrical wiring in electrical trade in the respective country / region of installation.
  • Page 3 · Zone 22 classified locations (areas where ignitable concentrations of combustible dust or ignitable fibers/flyings are not likely to exist under normal operating conditions). 1. Please check that your HEATSCOPE radiant heater and accessories are complete and not ®...
  • Page 4 IP protection class ® IP24. Nevertheless, it is mandatory to install the unit on a surface where it is well protected from any weather influences like rain and dust from above; so the HEATSCOPE has to be ®...
  • Page 5 HEATSCOPE during operation and up to 30 minutes after switching it off. ® 7. For your own safety, never dry textiles or other materials using the HEATSCOPE . Covering ® the radiant heater may result in a fire! Always maintain a distance from the heating surface of the HEATSCOPE of at least 60.00 inch from textiles, cloth and other easy inflammable soft...
  • Page 6 M U N I C H H O M E S Y S T E M S the guarantee. Improper repairs and incorrect installation or operation shall invalidate the guarantee immediately. 13. If the heater was installed inappropriately or was connected unhomogeneously with the local electrical supply cable, high transfer resistances may occur, which lead to overheating of the device.
  • Page 7 If the HEATSCOPE® is installed in such an environment with high humidity, the switches or other operating components must be positioned in such a way that they cannot be touched by per- sons who are in direct contact with water.
  • Page 8 M U N I C H H O M E S Y S T E M S CeiLinG inStaLLation ≤ A ≥ B ≥ B a (inch) B (inch) a (inch) B (inch) ≤ 9.45 ≥ 5.35 ≤ 11.85 ≥ 6.90 MHS-SP1600 MHS-VE1600/MHS-VT1600 MHS-SM2200/MHS-SP2200...
  • Page 9 A M B I E N T H E A T I N G S O L U T I O N S WaLL moUntinG ≤ A ≥ B ≥ B ≤ A ≤ A ≥ B ≥ B ≥ B ≥...
  • Page 10 M U N I C H H O M E S Y S T E M S MAD Design USA · 5875 Green Valley Circle, Suite 100 · Culver City / CA 90230 / USA...
  • Page 11 A M B I E N T H E A T I N G S O L U T I O N S ElECTrICAl ConnECTIon 110–120 V AC MHS-SP1600AB.250 MHS-SP1600BK.250 MHS-SP1600WT.250 HeatSCoPe ® 110-120 V AC 50/60 Hz i n P U t...
  • Page 12 ElECTrICAl ConnECTIon 220–240 V AC MHS-SP2200AB.200, MHS-SP2800AB.200, MHS-SP2200BK.200, MHS-SP2800BK.200, MHS-SP2200WT.200, MHS-SP2800WT.200 MHS-VT1600AB.200, MHS-VT2200AB.200, MHS-VT3200AB.200, MHS-VT1600BK.200, MHS-VT2200BK.200, MHS-VT3200BK.200, HeatSCoPe SP // HeatSCoPe ® ® MHS-VT1600WT.200, MHS-VT2200WT.200, MHS-VT3200WT.200 220-240 V AC 50/60 Hz i n P U t Circuit breaker / fuse switch...
  • Page 13 A M B I E N T H E A T I N G S O L U T I O N S MHS-SM1600AB.200, MHS-SM2200AB.200, MHS-SM2800AB.200, MHS-SM1600BK.200, MHS-SM2200BK.200, MHS-SM2800BK.200, MHS-SM1600WT.200, MHS-SM2200WT.200, MHS-SM2800WT.200 MHS-VE1600AB.200, MHS-VE2200AB.200, MHS-VE3200AB.200, MHS-VE1600BK.200, MHS-VE2200BK.200, MHS-VE3200BK.200, HeatSCoPe SP // HeatSCoPe ® ® MHS-VE1600WT.200, MHS-VE2200WT.200, MHS-VE3200WT.200 220-240 V AC 50/60 Hz i n P U t...
  • Page 14 M U N I C H H O M E S Y S T E M S manUaL ControL MHS-SM1600, MHS-SM2200, MHS-SM2800 MHS-VE1600, MHS-VE2200, MHS-VE3200 LeD: 100 % 50 % MAD Design USA · 5875 Green Valley Circle, Suite 100 · Culver City / CA 90230 / USA...
  • Page 15 A M B I E N T H E A T I N G S O L U T I O N S ir remote ControL MHS-SP1600, MHS-SP2200, MHS-SP2800 MHS-VT1600, MHS-VT2200, MHS-VT3200 LeD: / OFF   – 1  100 % ...
  • Page 16 M U N I C H H O M E S Y S T E M S minimum distances wall mounting The following installation regulations ensure that the HEATSCOPE ambient heater is working effectively. ® All minimum clearances that must be met regardless of the installation environment are listed.
  • Page 17 A M B I E N T H E A T I N G S O L U T I O N S The clearances given are minimum values and may differ from the local building and fire regulations. The latter must be observed and complied with in any case. Phone: +1 (888) 590 3335 ·...
  • Page 18 M U N I C H H O M E S Y S T E M S minimum distances wall mounting The following installation regulations ensure that the HEATSCOPE ambient heater is working effectively. ® All minimum clearances that must be met regardless of the installation environment are listed.
  • Page 19 A M B I E N T H E A T I N G S O L U T I O N S The clearances given are minimum values and may differ from the local building and fire regulations. The latter must be observed and complied with in any case. Phone: +1 (888) 590 3335 ·...
  • Page 20 M U N I C H H O M E S Y S T E M S minimum distances wall mounting The following installation regulations ensure that the HEATSCOPE ambient heater is working effectively. ® All minimum clearances that must be met regardless of the installation environment are listed.
  • Page 21 A M B I E N T H E A T I N G S O L U T I O N S The clearances given are minimum values and may differ from the local building and fire regulations. The latter must be observed and complied with in any case. >...
  • Page 22 Unpacking the unit / packaging Unpack the unit and the accessories carefully. When opening the packaging, do not use sharp objects that could damage the unit. This product comes supplied in environmentally friendly packaging. All HEATSCOPE packaging that ® comes into circulation either directly or via the trade is certified in accordance with §6 of the German Packaging Directive.
  • Page 23 Use only a very soft cloth or a brush for the reflector and the heating elements. CaUtion! Do not use a high pressure hose or other high pressure water equipment to clean HEATSCOPE ® ambient heaters. Do not use any sharp objects and aggressive cleaning agents under no circum stances.
  • Page 24 The unit must be disposed of professionally and in an environmentally friendly manner. The relevant legal regulations must be observed. Guarantee and warranty The HEATSCOPE is guaranteed for 24 months. The warranty period begins on the date on which the new ®...
  • Page 25 A M B I E N T H E A T I N G S O L U T I O N S models HeatSCoPe SPoT – manual control, 4 core cable ® SPECIFICATIONS: ON/OFF + 2 manually switchable power levels (100% or 50%) MHS-SM1600AB.250, MHS-SM2200AB.200, MHS-SM2800AB.200...
  • Page 26 M U N I C H H O M E S Y S T E M S teCHniCaL Data HEATSCOPE SPOT HEATSCOPE VISION ® ® Operating voltage 110-120 V AC, 50/60 Hz Power at 115 V AC 1600 W Current 13.91 A...
  • Page 27 MHS-VT3200 / MHS-VE3200 3200 W 11.0 kg 1660 x 184 x 87 mm MHS – HEATSCoPE VISIon AnD SPoT – WIrIng / ConnECTIng rEgulATIon ® Pillar terminal 1000 K / 3 + 4 MDS HT 0.02–0.24 inch², 3 + 4 pol.
  • Page 28 M U N I C H H O M E S Y S T E M S inStaLLation aSSiStanCe for mHS HeatSCoPe ViSion anD SPot infrareD HeaterS ® Professional and safe installation of HeatSCoPe ViSion and SPot heaters acc. to int. standards: ® Standards:...
  • Page 29 A M B I E N T H E A T I N G S O L U T I O N S Professional and safe electrical connection of HeatSCoPe heaters acc. to int. standards: ® Standards: The electrical installation must be done by a professional electrician acc. to DIN VDE 0298-4 / IEC 60364-5-52, current load of electrical wirings / connections acc.
  • Page 30 M U N I C H H O M E S Y S T E M S tHe foLLoWinG inStrUCtionS anD markinGS mUSt Be oBSerVeD anD ComPLieD WitH in any CaSe anD UnDer any CirCUmStanCeS. Care inStrUCtionS Care inStrUCtionS! important! Before first use, please clean the heater surface with an alcohol-free customary glass cleaner.
  • Page 31 A M B I E N T H E A T I N G S O L U T I O N S GeneraL inStrUCtionS BaSeD on internationaL StanDarDS anD SPeCifiCationS ul499 Cl. 53.15: CaUtion! a) Have a qualified electrician install a properly grounded receptacle outlet, acceptable for outdoor use and protected from snow and rain, immediately adjacent to the location where the heater will be used.