Installation Guide

2.13 Field Installation

CAUTION
• Only trained and qualified personnel should install this equipment
• Only a licensed electrician should install power cable / energize circuits
• All device wiring must follow the National Electric Code (NEC) or wiring requirements in the country of
installation. All location building and structure codes must be observed
• Ensure that the power source for the AP 7181 is de-energized prior to installation
WARNING!
• Avoid exposure to high voltage power sources
• Avoid contact with overhead power lines
• Avoid falling tools or equipment
• Be aware of vehicular traffic in the vicinity of the work area
WARNING!

2.13.1 Bottom Mount Installation

The pole mount adapter (Part Number RLN6197A) will accommodate a banding strap up to 1¼ inch width. Banding
straps and the banding tool are not included when ordering the pole mount adapter. The banding straps
recommended for the pole mount adapter are 3/4 inch 201 Stainless Steel BAND-IT BAND
(http://www.band-it-index.com) or better. Two bands are required for each mounting kit.
Observe the following precautions to avoid damage to the unit during installation:
Observe the following safety precautions to avoid personal injury during installation:
When disconnecting antenna cables from the unit or removing an antenna panel and
replacing it with a blank panel, terminators MUST be placed on the unused connectors
on the top of the unit. The terminators for the AP 7181 are Ingress Protection 68 (IP68)
rated. No additional weatherproofing precautions are required.