AP-7161 Access Point Installation Guide

Hardware Installation

The AP-7161 access point has the following port designations:
• GE1/POE - LAN Port
• GE2 - WAN Port
• Console Port
An AP-7161 must be installed by trained professionals familiar with RF planning and regulatory limits defined by the regulatory
bodies of the country where the devices are being deployed. All common precautions for grounding and ESD (Electrostatic
Discharge) protection should be observed during deployment and installation. AP-7161 devices must be installed such that no
harmful interference results from device operation.
CAUTION
WARNING!

Precautions

Before installing an AP-7161 model access point verify the following:
• Become familiar with all grounding requirements (see
• The grounding cable for an AP-7161 must be a #10 gauge wire cross section. The cable can be attached to the unit using
one of the three recommended methods:
Loosen the grounding screw, insert the grounding cable into the hole below it and tighten the screw.
Loosen the grounding screw, wind the grounding cable around and tighten the screw.
Attach a ring lug to the grounding cable and secure it to the unit using the grounding screw.
• Verify that the deployment environment has a continuous temperature range compatible with the operating temperature
range of the device.

Warnings

• Read all installation instructions and site survey reports, and verify correct equipment installation before connecting the
access point to its power source.
• Remove jewelry and watches before installing this equipment.
• Verify that the unit is grounded before connecting it to the power source.
• Verify that any device connected to this unit is properly wired and grounded.
• Connect all power cords to a properly wired and grounded electrical circuit. Verify that the electrical circuits have appropriate
overload protection.
• Attach only approved power cords to the device.
• Verify that the power connector and socket are accessible at all times during the operation of the equipment.
All device wiring must comply with the National Electric Code (NEC) or
regulations and procedures defined by the regulatory bodies of the country or
region where the devices are being deployed. All local building and structure
codes must be observed.
Strictly observe the following Safety Warnings and Precautions when installing