Motorola AP 7181 Installation Manual page 30

Hide thumbs Also See for AP 7181:
Table of Contents

Advertisement

30
10. Torque the allen socket head screws to between 108.7 and 145.0 Inch Pounds (lbf-in).
CAUTION
11. The set screw can now be inserted to increase stability. Tighten the set screw from 214.2 - 250.0 inch
pounds (lbf-in).
NOTE
12. If the AP 7181 is a Mesh Point Root node or a Mesh Point node with an external device (e.g. surveillance
camera), perform the required Ethernet cabling.
The Ethernet cable gland is optimized for cables of diameter .39 - .55 inches. Smaller diameter cables can
achieve a watertight seal if the cable gland is properly tightened during installation. It is recommended
that an outdoor UV rated shielded cable is used in AP 7181 deployments. Examples are:
• Superior Essex 04-001-55
• Best-Tronics BT-0562
In most cases, Ethernet cable is custom cut to length. After preparing the Ethernet cable and attaching
shielded RJ-45 end connectors, feed the cable through the cable gland cap and rubber insert as shown
below.
13. Insert the data cable through cable gland (i.e. the cable gland on Gigabit Ethernet port GE1).
Ensure the allen socket hex screws are tight and in the locked position before
releasing the full weight of the Access Point.
Only one set screw is included with each AP 7181 kit. If a second set screw is required,
purchase an M14x2.0, 20mm stainless steel Hexagonal screw.
AP 7181 Access Point

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents