(H) Receiving 999 kHz
(I)
AM Local Mode
(J) S. Meter Adj. Mode
7. Press the t TA/AF button in the step 1, the unit enters the S meter adjustment mode. Rotate the R204 on Main PCB to adjust the LCD
until the 0.95 lights up Fig. 9 (J)
8. e POWER OFF and ON. Release the test mode.
9. e POWER ON and press the y PRESET 5 .
SG 98.1 MHz, MOD. 75 kHz, INT MOD. EXT, att 66dBµ
RDS 1.0%, MOD. 30% 1 kHz, MONO, RDS ON, TP ON, SK OFF, BK OFF.
10. Confirm the " TP " indicator on the LCD lights up.
Fig. 9 (K)
(L) soon. So RDS ON Sensitivity is OK.
11. Press the q PRESET 1 button for more than 2 seconds. (Memorize the RDS).
12. Press the t TA/AF button for more than 2 seconds and confirm the " AF " indicator on the LCD lights up. Fig. 9 (M)
SG 107.1 MHz, MOD. 75 kHz, INT MOD. EXT, att 66dBµ
RDS 1.6%, MOD. 30% 1kHz, MONO, RDS ON, TP ON, SK OFF, BK OFF.
13. Press the q PRESET 1 button. Confirm the receiving 107.1 MHz automatically. So the LCD indicator displays Fig. 9 (O)
ALIGNMENT OF CASSETTE PLAYER
See the wow/flutter meter for JIS/WRMS function.
SET
MODULATION
STEP
FREQUENCY
1
Head Azimuth
2
Wow/Flutter
3
Tape Speed
(K) The moment TP ON
(L) Change the Display while TP ON
(M) The Moment AF ON
Fig. 9
(See Fig. 1.3)
DUMMY
LOAD &
SW BOX
Fig. 4
OUTPUT
TEST TAPE
INDICATOR
MTT-257E
VOLTMETER
MTT-111N
Wow/Flutter Meter
(3kHz)
MTT-111N
Tape Speed Drift
(3kHz)
Meter
— 10 —
(N) Change the Display while AF ON
(O) The Moment 107.1MHz Receiving
(P) Change the Display while 107.1MHz Receiving
AC VOLTMETER
WOW/FLUTTER METER
(with drift meter)
Align azimuth (on Head) for maximum
output 10 kHz as well as baiance on 1 kHz
between Left and Right channel output.
Check the display less than 0.3%
(JIS/WRMS).
Check the display within -1% and +3%.
(N) soon.
(P).
REMARKS