108
Chapter 6 Command line interface
Table 39 Information fields for output of the show ports stats pos felineinterval
command
Field
PORT NUM
ERRORED SECONDS
COUNT (ES)
SEVERELY ERRORED
COUNT (SES)
CODE VIOLATION COUNT
(CV-L)
UNAVAILABLE SECONDS
(UAS)
INTERVAL ID
show ports stats pos fepathcurrent
This command displays current statistics
at the receiving end. The command uses the syntax:
show ports stats pos fepathcurrent
Figure 39 show ports stats pos fepathcurrent command output
Passport-8610:5/show/ports/stats/pos# fepathcurrent
=========================================================================
=========================================================================
PORT
ERRORED SECONDS
NUM
COUNT (ES)
-------------------------------------------------------------------------
10/1
0
10/3
0
Passport-8610:5/show/ports/stats/pos#
209564-A
Description
Port number.
Errored Second (ES) is a second with one or more Coding
Violations (CV) or one or more incoming defects (for
example, SEF, LOS, AIS, LOP).
Severely Errored Second (SES) is a second with x or more
CVs, or one or more incoming defects.
Coding Violations (CV) are Bit Interleaved Parity (BIP)
errors that are detected in the incoming signal. CV
counters are incremented for each BIP error detected.
Number of seconds that the interface is unavailable.
Specified interval.
POS Far End Path Current Stats
SEVERELY ERRORED
COUNT (SES)
0
0
(Figure
39) for the far end path, which is
[
<ports>
]
CODE VIOLATION
COUNT (CV-P)
0
0
UNAVAILABLE
SECONDS(UAS)
0
527