Adjusting Salt Consumption - Sandstrom SDW60W10N Instruction Manual

Hide thumbs Also See for SDW60W10N:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

Adjusting Salt Consumption

To optimise and customise the level of salt consumption, please
follow the steps below to adjust the salt consumption.
1. Remove the lower basket and unscrew the reservoir cap.
2. There is an arrow-shaped indicator in the reservoir, which allows
you to turn. You may turn it to the "-" or "+" settings based on the
water hardness in your area.
It is recommended that adjustments should be made in accordance with the following chart.
WATER HARDNESS
˚dh
GB
0-8
8-22
14-39
22-45
39-80
>45
1 ˚dh (German degree) = 1.25mmol/l
18
SDW60W_X10N_IB_5L_100921.indb 18
˚fh
˚Clark
mmol/l
0-14
0-10
0-1.4
10-28
1.4-3.9
28-56
3.9-8
>80
>56
>8
1 ˚fh (French degree) = 0.178mmol/l
Selector
Salt Consumption
Position
(gram/cycle)
/
0
-
20
Mid
40
+
60
1 ˚Clark (British degree) = 1.78mmol/l
Turn
Auto nomy
(cycle/1.2 kgs)
/
60
30
20