Care and Maintenance
The machine must be disconnected from the power supply when
servicing work is being carried out. The main switch should be in
position "0" and the plug out of the socket.
Weekly, or after approx. 40 hours of operation:
- Check the oil level of the high pressure pump. If the oil level is too low, add oil until
the oil level is between the two markings on the oil measuring rod.
Change the oil if it has a grey or whitish appearance. The oil should be
disposed of responsibly.
- Check the water filter in front of the float valve in the water tank and the fuel filter
in front of the solenoid valve. Clean the filters if necessary.
Yearly, or after approx. 500 hours of operation:
- Check and decalcify continous flow heater, if necessary.
- Change the oil
Change the oil:
Oil leakage: If oil leaks out, go to the nearest customer service
(dealer) immediately. (Environmental damages, transmission damages)
In case of increased humidity or fluctuations in temperature
development of condensed water is possible; if the oil turns grey, you
must change it at once.
First oil change after approximately
50 operating hours. Thereafter the oil
should be changed every 500 operating
hours or yearly.
Take the oil drainage hose, which is
connected to the oil drainage screw from the
inside of the appliance.
Open the red oil filler plug at the top side of
the black oil housing.
Open the cap at the end of the hose. Drain
off the oil into an oil pan and dispose of it
responsibly. Close the end of the hose. Refill
with new oil. Oil grade Castrol 10/W-60,
approx. 0.8 l.