Mantenimiento; Pipe Lengths - Viqua H, K Owner's Manual

Hide thumbs Also See for H, K:
Table of Contents

Advertisement

13
13
14
14
1
• Vuelva a instalar la junta
• Conecte el perno de la vaina
tórica en la parte inferior de la
tubular en la parte inferior.
vaina tubular.
• Cuando haya finalizado el
servicio, realice los pasos que
aparecen en los requisitos
previos en orden inverso al
desmontaje.
Nota: Tras reemplazar la lámpara UV o la vaina tubular, realizar el procedimiento de desinfección, consulte la
4.3 Reposición de fusibles
El sistema viene equipado de dos fusibles 3A de 250 V en funcionamiento. Para acceder a los fusibles, primero desenchufe
el sistema y desconecte el cable de alimentación del controlador. Para extraer el fusible, presione la pestaña en un lado con
un cuchillo u otra herramienta y tire de ella suavemente hacia afuera. Repita el proceso en el otro lado.
Procedimiento:
1
2
• Desconecte el controlador del
• Reemplace el fusible.
sistema.
4.4 Mantenimiento del sensor de medidor de flujo
Inspeccione periódicamente el sensor de medidor de flujo para asegurarse de que no hay suciedad y que la rueda de
paletas gira libremente, sin resistencia.
Si la rueda de paletas no gira libremente o está suelta, deberá enviarse el sensor para ser reparado y calibrado. Para
garantizar un funcionamiento preciso del sistema, es recomendable enviar el sensor de medidor de flujo para calibrarlo
cada dos años.
2
3

Mantenimiento

General Information
6
Solenoid valve
7
Sample valve
8
Plug
9
Sensor
10
UV chamber
11
CoolTouch™ fan
12
Sample valve
13
Shut-off valve
14
Controller
15
Power source
Sección
3.2.
16
Flow Sensor
Item
PRO10
21.4" (55 cm)
PRO20, H Plus, H
31" (78 cm)
PRO30
41" (103 cm)
PRO50, K Plus, K
41" (103 cm)

2.2 Pipe Lengths

The recommended minimum straight pipe lengths for the various piping configurations are:
Straight Flange 10" straight pipe
2 x 90 degree Elbows 3 dimensions 40" straight pipe
Note: Flow Meter Sensor must be mounted in the following orientation with the LED facing up. Ensure all air is purged from
the piping and Flow Meter Sensor. All straight length to the Flow Meter Sensor must be 1.00" in diameter.
54
7
Allows water supply to be shut-off when proper disinfection cannot be assured.
Note: If the ground from your electrical panel is tied to your copper water lines, and you
are using a Plastic Body solenoid valve, installation of an approved ground strap is
required. This ground strap will maintain continuity between the lines that have been cut
to install the solenoid. Check your local electrical code for the correct clamp and cable
size.
Allows for sampling of water entering UV chamber; necessary in order to confirm water
being treated is of adequate quality.
A stopper provided and installed on Basic models.
Monitors UV output to ensure proper dose (UV exposure) is being provided.
Provides disinfection of the water. MUST BE INSTALLED VERTICALLY.
Removes excess heat from water in chamber during periods without water flow.
Allows for sampling of water immediately following UV treatment; necessary in order to
confirm proper operation of UV system.
Allows maintenance of UV system.
Powers and controls the UV lamp and other devices. Provides human interface,
displaying information and allowing control inputs (such as muting the audible alarm).
Provides power to the controller. For safety reasons the outlet must be protected by a
Ground Fault Circuit Interrupter (GFCI).
Note: To protect the controller, a UL1449 certified (or equivalent) transient voltage surge
suppressor is required.
Monitors flow to provide real time dose (UV exposure) Flow Meter Sensor must be
installed in this orientation with the LED facing up. (PRO10, PRO20, PRO30 only)
L
S (minimum)
O
A (maximum)
12" (30 cm)
4" (10 cm)
72" (182 cm)
12" (30 cm)
4" (10 cm)
72" (182 cm)
12" (30 cm)
4" (10 cm)
72" (182 cm)
12" (30 cm)
4" (10 cm)
72" (182 cm)
Reducing Flange 15" straight pipe
Pump 50" straight pipe
B
C
D
6.5" (16.5 cm)
13" (33 cm)
48" (122 cm)
6.5" (16.5 cm)
13" (33 cm)
48" (122 cm)
6.5" (16.5 cm)
13" (33 cm)
48" (122 cm)
6.5" (16.5 cm)
13" (33 cm)
48" (122 cm)
2 x 90 degree Elbows 25" straight pipe

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H plusK plusPro10Pro20Pro30Pro50

Table of Contents