Viqua G+ Instruction Sheet
Viqua G+ Instruction Sheet

Viqua G+ Instruction Sheet

Sensor replacement

Advertisement

Instruction Sheet
VIQUA Sensor Replacement
Models:
G+, H+, J+, K+, PRO10, PRO20, PRO30, PRO50 and PRO24-186
Section 1
Safety Information
Please read this entire instruction sheet before operating this equipment. Pay attention to all danger, warning, and caution
statements in this instruction sheet. Failure to do so could result in serious personal injury or damage to the equipment.
Make sure that the protection provided by this equipment is not impaired. Do not use or install this equipment in any manner
other than that specified in the instruction sheet.

1.1 Safety Precautions

Failure to follow these instructions will result in serious injury or death.
Shock Hazard - Stored Energy
Disconnect power to system before performing any maintenance or repair.
There may be more than one source of power. Only connect to a GFCI.
Protective ground
DO NOT touch with wet hands.
Pressurized Device - Impalement Hazard
NEVER perform any physical inspection, repair or maintenance on UV chamber unless UV chamber has been isolated and depressurized.
NEVER service UV lamps, quartz sleeves or associated hardware until depressurization of UV chamber has been confirmed.
DO NOT store any combustible or flammable material close to the system.
Failure to follow these instructions could result in serious injury or death.
UV Light Hazard
UV
ALWAYS use UV protective gear, including gloves and UV safety glasses.
NEVER look directly at illuminated UV lamp, even when using protective gear.
NEVER illuminate UV lamp outside of the UV chamber.
If accidental exposure occurs, immediately cool affected area and consult physician.
Contamination Hazard
If UV lamp breaks, avoid inhalation, ingestion, or exposure to eyes and skin. Wear appropriate clothing and personal protective equipment.
NEVER use a vacuum cleaner to clean up broken UV lamps as this will scatter the mercury. Obey local regulations and guidelines for the removal
and disposal of mercury waste.
WARNING: This product can expose you to chemicals including Phthalates, which are known to the State of California to cause cancer and birth
defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
D A N G E R
WA R N I N G
602964_RevP

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G+ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Viqua G+

  • Page 1: Section 1 Safety Information

    Instruction Sheet VIQUA Sensor Replacement Models: G+, H+, J+, K+, PRO10, PRO20, PRO30, PRO50 and PRO24-186 Section 1 Safety Information Please read this entire instruction sheet before operating this equipment. Pay attention to all danger, warning, and caution statements in this instruction sheet. Failure to do so could result in serious personal injury or damage to the equipment.
  • Page 2: Maintenance

    Maintenance C A U T I O N Failure to follow these instructions could result in minor or moderate injury. Thermal Hazard • Allow UV lamps, UV chamber to cool for a minimum of 10 (ten) minutes before handling. • When there is no water flow, the water in the chamber will become hot.
  • Page 3: Disinfection Procedure

    Maintenance Solenoid • Restore power. • Remove the old sensor from • Turn on water supply. • Connect the sensor cable UV chamber. (blue). • Install the new sensor to UV chamber. Note: After replacing the UV sensor perform the disinfection procedure, refer to Section 2.2.
  • Page 4 Maintenance 30 mins • Remove both cartridges and • Reinstall the housings. • Allow the water to fill UV • Open all faucets and turn on disinfect the housings with Chamber. the cold water supply household bleach solution. followed by hot water (if available) until you smell the Note: DO NOT use bleach.
  • Page 5 425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1 t. (+1) 519.763.1032 • tf. (+1) 800.265.7246 (US and Canada only) t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069 e-mail: info@viqua.com www.viqua.com...