c.
Attaching the Corona Wires for the Primary and
Transfer Corona Units
n Primaty Corona Unit
1) Remove the four tension springs and grid plate.
Figure 4-69
n Transfer Corona Unit
2) Remove the guide wire retainer; see p. 4-22.
3) Loosen a length of about 40 mm of corona wire
from a 0.06-dia. wire reel, and form a loop at the
end with a diameter of about 2 mm.
Note:
To form a loop, wind the corona wire around
a hex key once, and turn the key four to five
times; thereafter, twist the wire.
4)
5) Hook the loop of the corona wire as shown in
6)
7) Pick the end of the corona wire tension spring
CANON NPZf20/2MO RN.0 MAY 1990 PRINTED IN JAPAN IIMPRIME AU JAPONI
Cutofftheend(excess)ofthecoronawiretoless
than 1 mm using a nipper.
Figure 4-70, and fit the wire along the V-groove
of the height adjusting block.
Hook the corona wire tension spring on the
corona wire, and turn the spring three to four
times as shown in Figure 4-70.
Figure 4-70
Cutofftheend(excess)ofthecoronawiretoless
than 1 mm using a nipper.
using tweezers, and hook it on the corona
electrode.
Note:
n Check that the corona wire is free of twist
and its gold-plating is intact.
if the length of the tension spring is about
12 mm.
n Check that the corona wire is fitted along
4-23