Initialization Of B, E, F, 7, 9 Page Data; Initializing B, E, F; Modification Of B, E, F - Sony MVC-FD100 Service Manual

Hide thumbs Also See for MVC-FD100:
Table of Contents

Advertisement

MVC-FD100/FD100H/FD200/FD200H
1-2-2.

Initialization of B, E, F, 7, 9 Page Data

1. Initializing B, E, F, 7, 9 Page Data
Note: If the B, E, F, 7, 9 Page data has been initialized,
"Modification of B, E, F, 7, 9 Page Data" and following
adjustments need to be performed again.
1) Modification of B, E, F, 7, 9 page data
2) Video system adjustments
3) Camera system adjustments
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Initializing Method:
Order Page Address Data
1
0
01
2
6
00
3
6
01
4
6
02
5
6
03
6
6
00
7
6
01
8
6
02
9
Note: Type of CCD imager is different according to the CD board
in MVC-FD100.
Refer to page 7 to discriminate the type of CCD.
B
00 to FF
E
00 to FF
F
10 to FF
7
00 to FF
9
00 to FF
Procedure
01
FF
FF
Press PAUSE button.
Check the data changes to "01".
Set the following data, and
press PAUSE button.
FD100 (Note)
15: TYPE PA
17: TYPE SO
FD200
16
2D
2D
Press PAUSE button.
Check the data changes to "01".
Perform "Modification of B,
E, F, 7, 9 page Data".
2. Modification of B, E, F, 7, 9 Page Data
If the B, E, F, 7, 9 Page data has been initialized, change the data
of the "Fixed data-2" address shown in the following tables by
manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the
camcorder may not operate.
3) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of B, E, F, 7, 9 Page
data
Order Page Address Data
1
2
00
2
2
01
3. B Page Table
Note 1: Fixed data-1: Initialized data.
(Refer to "1. Initializing B, E, F, 7, 9 Page Data")
Note 2: Fixed data-2: Modified data.
(Refer to "2. Modification of B, E, F, 7, 9 Page Data")
Address Initial value
00 to 74
75
76 to FF
4. E Page Table
Note 1: Fixed data-1: Initialized data.
(Refer to "1. Initializing B, E, F, 7, 9 Page Data")
Note 2: Fixed data-2: Modified data.
(Refer to "2. Modification of B, E, F, 7, 9 Page Data")
Address Initial value
00 to AD
AE
AF to FF
Note 3: Type of CCD imager is different according to the CD
board in MVC-FD100.
Refer to page 7 to discriminate the type of CCD.
5-10
Procedure
29
29
Press PAUSE button.
Remark
Fixed data-1 (Initialized data)
Fixed data-2
Fixed data-1 (Initialized data)
Remark
Fixed data-1 (Initialized data)
Fixed data-1 (Initialized data)
(FD100: TYPE PA/FD200)
Fixed data-2 (FD100: TYPE SO)
(Note 3)
Fixed data-1 (Initialized data)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mvc-fd100hMvc-fd200Mvc-fd200h

Table of Contents