Hall Adjustment - Sony MVC-FD100 Service Manual

Hide thumbs Also See for MVC-FD100:
Table of Contents

Advertisement

MVC-FD100/FD100H/FD200/FD200H

1. HALL Adjustment

Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: The right two digits of the page: 1 displayed data of the
adjusting remote commander.
1:00:XX
Adjusting method:
Order Page Address Data
1
2
6
94
3
6
95
4
6
01
5
6
02
6
6
01
7
0
03
8
6
01
9
1
10
6
01
11
1
Note 3: The adjustment data will be automatically input to page:
F, address: 2E, 2F, 34 and 35.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
94
3
6
95
4
0
03
5
RadarW
RadarW
RadarW
RadarW
RadarW
CAMERA
Not required
Displayed data of page: 1
(Note 2)
Adjusting remote commander
F
2E, 2F, 34, 35
10 to 18 during IRIS OPEN
75 to 7D during IRIS CLOSE
Displayed data
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-16)
14
79
Press PAUSE button.
6D
(Note 3)
Check the data changes to
"01".
00
Press PAUSE button.
03
01
Press PAUSE button.
Check that the displayed data
(Note 2) during IRIS OPEN
satisfied the specified value.
03
Press PAUSE button.
Check that the displayed data
(Note 2) during IRIS CLOSE
satisfied the specified value.
Procedure
00
Press PAUSE button.
00
00
00
Release the data setting
performed at step 1.
(Refer to page 5-16)
5-18