Initialization Of B, D, E, F, 7 Page Data; Initialization Of D Page Data; Initializing The D Page Data; Modification Of D Page Data - Sony MVC-FD85 Service Manual

Digital still camera
Hide thumbs Also See for MVC-FD85:
Table of Contents

Advertisement

1-2.

INITIALIZATION OF B, D, E, F, 7 PAGE DATA

1-2-1.

INITIALIZATION OF D PAGE DATA

1. Initializing the D Page Data

Note: If the D page data has been initialized, the following adjustments
need to be performed again.

1) Modification of D page data

2) LCD system adjustments
3) Battery end adjustment
4) Zoom key center adjustment
Adjusting page
D
Adjusting Address
10 to FF
Initializing Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 2, address: 03, and set the following data.
05: MVC-FD85
04: MVC-FD90
3) Select page: 2, address: 00, and set data: 2D.
4) Select page: 2, address: 01, set data: 2D, and press the PAUSE
button of the adjustment remote commander.
5) Select page: 2, address: 02, and check that the data changes to
"01".
6) Perform "Modification of D Page Data".
2. Modification of D Page Data
If the D page data has been initialized, change the data of the "Fixed
data-2" address shown in the following table by manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camera may
not operate.
3) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of D Page data
1) Select page: 2, address: 00, and set data: 29.
2) Select page: 2, address: 01, and set data: 29, and press the
PAUSE button of the adjustment remote commander.
3. D Page Table
Note:
Fixed data-1: Initialized data. ( Refer to "1. Initializing the D Page Data").
Fixed data-2: Modified data. (Refer to "2. Modification of D Page Data").
Address
Initial value
FD85
FD90
00 to 0F
10
00
00
11 to 1D
1E
1F to 61
62 to 63
64 to 66
67
00
00
68
69
6A
6B
6C
00
00
6D
00
00
6E
00
00
6F
00
00
70
71 to 77
78 to 7D
7E to 7F
80 to 87
88
89
80
80
8A to 8B
8C to 8F
90
80
90
91
88
98
92
AD
A7
93
C2
BC
94
CD
C7
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
5-8
Remark
Test mode
Fixed data-1 (Initialized data)
Fixed data-2 (Modified data. Copy
the data built in the same model.)
Fixed data-1 (Initialized data)
Fixed data-2 (Modified data. Copy
the data built in the same model.)
Fixed data-1 (Initialized data)
Flash unit emergency
Fixed data-1 (Initialized data)
Recording counter
Recording counter/MC CAM (FC-72
board IC501) emergency
Fixed data-2 (Modified data. Copy
the data built in the same model.)
Fixed data-1 (Initialized data)
Fixed data-2 (Modified data. Copy
the data built in the same model.)
Fixed data-1 (Initialized data)
Fixed data-2 (Modified data. Copy
the data built in the same model.)
Fixed data-1 (Initialized data)
Zoom key center adj.
Fixed data-2 (Modified data. Copy
the data built in the same model.)
Fixed data-1 (Initialized data)
Battery end adj.
Fixed data-1 (Initialized data)
Fixed data-2 (Modified data. Copy
the data built in the same model.)