P-Sig Level Adjustment (Pk-61 Board) - Sony MVC-FD100 Service Manual

Hide thumbs Also See for MVC-FD100:
Table of Contents

Advertisement

7. P-SIG Level Adjustment (PK-61 Board)

This adjustment sets correctly the V-COM drive signal level of the
LCD panel.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 8 of CN803 on FC-89 board
(COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
DA
A=5.0 ± 0.1 Vp-p
Specified Value
Adjusting method:
Order Page Address Data
1
0
01
01
2
D
DA
3
D
DA
Processing after Completing Adjustment:
Order Page Address Data
1
0
01
00
A
Fig. 5-1-26
Procedure
Change the data and set the
voltage (A) to the specified
value.
Press PAUSE button.
Procedure
2H
MVC-FD100/FD100H/FD200/FD200H
5-39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mvc-fd100hMvc-fd200Mvc-fd200h

Table of Contents