Lcd Initial Data Input - Sony MVC-FD100 Service Manual

Hide thumbs Also See for MVC-FD100:
Table of Contents

Advertisement

1. LCD Initial Data Input

Mode
PLAY
Signal
Arbitrary
Adjustment Page
D
Adjustment Address
D0 to DF
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, and enter the data given in the following table.
Note: Press the PAUSE button each time the data are set, as the
data are written to non-volatile memory (EEPROM).
Address
Data
D0
82
D1
AB
D2
80
D3
B8
D4
CC
D5
5E
D6
80
D7
78
D8
60
D9
6C
DA
64
DB
00
DC
AA
DD
84
DE
44
DF
00
Processing after Completing Adjustments:
1) Select page: 0, address: 01, and set data: 00.
Remark
Bright Adjustment
Fixed value
White Balance Adjustment
Contrast Adjustment
Black Limit Adjustment
VG Center Adjustment
VCO Adjustment (NTSC)
V-COM Adjustment
Fixed value
P-SIG Level Adjustment
Fixed value
VCO Adjustment (PAL)
Fixed value