7. Light Value Adjustment
Adjust the standard LV value.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: 1 (Note
2) and page: F, address: 28
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
26 to 28
Specified Value
FD100 (Note 3):
FD200:
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Note 3: Type of CCD imager is different according to the CD
board in MVC-FD100.
Refer to page 7 to discriminate the type of CCD.
Adjusting method:
Order Page Address Data
1
2
3
6
01
0D
4
6
02
5
0
03
06
6
1
7
F
28
Note 4: The adjustment data will be automatically input to page:
F, address: 26 to 28.
RadarW
RadarW
RadarW
RadarW
RadarW
TYPE PA:
AE level 1: 0FE0 to 1020
AE level 2: 20 to 60
TYPE SO:
AE level 1: 0FE0 to 1020
AE level 2: 28 to 48
AE level 1: 0FE0 to 1020
AE level 2: 30 to 50
Displayed data
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-16)
Perform "Picture Frame
setting".
(Refer to page 5-17)
Press PAUSE button.
(Note 4)
Check the data changes to
"01".
Check that the displayed data
(Note 2) satisfies the AE
level 1 specified value.
Check that the displayed data
satisfies the AE level 2
specified value.
MVC-FD100/FD100H/FD200/FD200H
Processing after Completing Adjustment:
Order Page Address Data
1
0
03
2
6
01
3
5-23
Procedure
00
00
Press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 5-16)