6.3.2
LEDs 1 and 2
The following states are displayed via the LEDs:
Com/S1
Trg/S2
Blink codes are used to signal warnings or error states:
Class S1
Error code S2
FPGA Boot error
Stack setup
Stack start
No FLASH object
No DCAM object
Register mapping
VMode_ERROR_STATUS
FORMAT_7_ERROR_1
FORMAT_7_ERROR_2
The following sketch illustrates the series of blinks for a Format_7_error_1:
You should wait for at least 2 full cycles because the display of blinking codes starts
asynchronously – e.g. on the second blink from S2.
6.4
Operating the camera
Power for the camera is supplied either via the FireWire™ bus or via the HiRose plug.
The input with the highest voltage provides power to the camera.
The input voltage must lie within the following range:
Vcc min.: + 8V
Vcc max.: +36V
16
asynchronous and isochronous data transmission active (indicated
asynchronously to transmission over the 1394 bus)
LED on – waiting for external trigger
LED off – receiving external trigger
Warning
DCAM
1 blink
2 blinks
1 blink
2 blinks
1 blink
2 blinks
3 blinks
Figure 11 Warning and error states
MISC
FPGA
3 blinks
4 blinks
1-5 blinks
1 blink
Stack
5 blinks
1 blink
2 blinks
Need help?