Txt; Uni - AMX MST-1001 Configuration Manual

Modero s series tabletop touch panel and landscape wall mount touch panel
Table of Contents

Advertisement

Button Commands (Cont.)

?TXT

^UNI

Modero S Series Touch Panels - Configuration & Programming Manual
Get the current text information.
• Syntax:
"'?TXT-<vt addr range>,<button states range>,<optional index>'"
• Variables:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons 1 = Off state and 2 = On state).
optional index = This is used if a string was too long to get back in one command. The reply will start at this index.
custom event type 1001:
Flag - Zero
Value1 - Button state number
Value2 - Actual length of string
Value3 - Index
Text - Text from the button
Text length - Button text length
Example:
SEND COMMAND Panel,"'?TXT-529,1'"
Gets the button 'OFF state' text information.
The result sent to the Master would be:
ButtonGet Id = 529 Type = 1001
Flag
= 0
VALUE1 = 1
VALUE2 = 14
VALUE3 = 1
TEXT
= This is a test
TEXT LENGTH = 14
Set Unicode text. For the ^UNI command (%UN and ^BMF command), the Unicode text is sent as ASCII-HEX nibbles.
• Syntax:
"'^UNI-<vt addr range>,<button states range>,<unicode text>'"
• Variables:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons 1 = Off state and 2 = On state).
unicode text = Unicode HEX value.
Example:
SEND_COMMAND Panel,"'^UNI-500,1,0041'"
Sets the button's unicode character to 'A'.
Note: To send the variable text 'A' in unicode to all states of the variable text button 1, (for which the character code is
0041 Hex), send the following command:
SEND_COMMAND TP,"'^UNI-1,0,0041'"
Note: Unicode is always represented in a HEX value. TPD4 generates (through the Text Enter Box dialog) unicode HEX
values. Refer to the TPDesign4 Instruction Manual for more information.
Programming