^KPS

PKEYP

@PKP

@PWD

^PWD

SETUP

Modero S Series Touch Panels - Configuration & Programming Manual
Set the keyboard passthru.
• Syntax:
"'^KPS-<pass data>'"
• Variables:
pass data:
<blank/empty> = Disables the keyboard.
0 = Pass data to G4 application (default). This can be used with VPC or text areas.
1 - 4 = Not used.
5 = Sends out data to the Master.
• Example:
SEND COMMAND Panel,"'^KPS-5'"
Sets the keyboard passthru to the Master. Option 5 sends keystrokes directly to the Master via the Send Output String
mechanism. This process sends a virtual keystroke command (^VKS) to the Master.
• Example 2:
SEND COMMAND Panel,"'^KPS-0'"
Disables the keyboard passthru to the Master.
Accepts keystrokes from attached USB keyboard or Virtual keyboard.
Present a private keypad. Pops up the keypad icon and initializes the text string to that specified. Keypad displays a '*'
instead of the numbers typed. The Prompt Text is optional.
• Syntax:
"'PKEYP-<initial text>'"
• Variables:
initial text = 1 - 50 ASCII characters.
• Example:
SEND COMMAND Panel,"'PKEYP-123456789'"
Pops up the Keypad and initializes the text string '123456789' in '*'.
Present a private keypad. Pops up the keypad icon and initializes the text string to that specified. Keypad displays a '*'
instead of the numbers typed. The Prompt Text is optional.
• Syntax:
"'@PKP-<initial text>;<prompt text>'"
• Variables:
initial text = 1 - 50 ASCII characters.
prompt text = 1 - 50 ASCII characters.
• Example:
SEND COMMAND Panel,"'@PKP-1234567;ENTER PASSWORD'"
Pops up the Keypad and initializes the text string 'ENTER PASSWORD' in '*'.
Set the page flip password. @PWD sets the level 1 password only.
• Syntax:
"'@PWD-<page flip password>'"
• Variables:
page flip password = 1 - 50 ASCII characters.
• Example:
SEND COMMAND Panel,"'@PWD-Main'"
Sets the page flip password to 'Main'.
Set the page flip password. Password level is required and must be 1 - 4.
• Syntax:
"'^PWD-<password level>,<page flip password>'"
• Variables:
password level = 1 - 4.
page flip password = 1 - 50 ASCII characters.
• Example:
SEND COMMAND Panel,"'^PWD-1,Main'"
Sets the page flip password on Password Level 1 to 'Main'.
Send panel to SETUP page.
• Syntax:
"'SETUP'"
• Example:
SEND COMMAND Panel,"'SETUP'"
Sends the panel to the Setup Page.