VERSION 06/2014
OPERATING MANUAL
5.2

MODE OF OPERATION

If the trigger guard (D) is operated when the trigger guard locking device (E) is released,
then the air valve opens fi rst. Atomizing air fl ows through the air connection (F) to the
air cap (I). The material valve opens only when approx. 1/2 of the trigger guard's path is
covered. The quantity of air for the atomization of the jet spray is preset via the external air
automatic controller. The spray pattern can be adjusted using the shaping air regulator (B).
5.3

PROTECTIVE AND MONITORING EQUIPMENT

The spray gun is secured with the locking device (E) (the locking device turned in the
spraying direction and fastened in the groove).
5.4

SCOPE OF DELIVERY

This AirCoat manual gun is available in two diff erent versions. The choice of air cap and
nozzle depends on the application, therefore these components are not included in the
scope of delivery. A selection guide for gun accessories can be found in Chapter 13.
5.4.1

VERSIONS FOR APPLICATION UP TO 25 MPA; 250 BAR; 3625 PSI

Order No. Designation
1
2313585
1
2315700
5.4.2

STANDARD EQUIPMENT

The standard equipment for guns includes:
Order No.
1
2316429
1
2311729
1
see Chapter 1.3 Operating manual in local language
1
394335
For special versions the delivery note applies.
ORDER NUMBER DOC2311730
GM 4700AC 25 MPa, NPSM1/4" product connection
GM 4700AC-H 25 MPa, NPSM1/4" product connection
(H = for processing heated material)
Designation
CE Declaration of Conformity
Operating manual, German
Spring cap 16 MPa; 160 bar; 2320 psi
GM 4700AC
20