Replacing The "Air" Sealing Ring - WAGNER GM 4700AC Operating Manual

Table of Contents

Advertisement

VERSION 06/2014
OPERATING MANUAL
10.6

REPLACING THE "AIR" SEALING RING

Shaping air and atomizer air not separate!
Poor spray pattern
Spray jet cannot be adjusted.
Treat the distributor seal (F) with care.
1. Relieve pressure from the gun and from the device in accordance with
Chapter 7.3.3.
2. Clean and decommission in accordance with Chapter 8.1.3.
3. Secure the gun with the locking device.
4. Unscrew the union nut with nozzle guard (33).
5. Remove the air cap (36) together with the nozzle (13).
6. Remove the defective sealing ring (14/F) with the help of pipe tongs or with a large
screwdriver.
7. Assembly: attach the new distributor seal (14/F) to the air cap (36).
8. Place the air cap, together with sealing ring (14/F), into the gun body.
9. Attach the union nut (33) and screw it in until the sealing ring snaps into place in
the mounting groove (audible snap).
10. Demount the union nut (33) and air cap (36) and complete the spray gun according
to Chapter 7.3.4.
ORDER NUMBER DOC2311730
NOTICE
1
4
14(F)
2
3
B_02390
13
36
33
GM 4700AC
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gm 4700ac-h

Table of Contents