17) Attaching the Punching Device
(
SPS/D-B1201M[HPⅡ Ⅱ ])
A. Remove the left, right bed covers. As in the figure,
adjust to place the needle plate support cover at the
center of the bed cylinder and fix the support plate
with the fixing screw 1 and fix the needle plate
support cover with the fixing screw 2.
B. When the support plate fixing is done, fix the sub-
support plate for left, right adjustment to the support
plate with the fixing screw 3.
[Caution]
Do not remove the safety plate to prevent accidents.
Do not put in hands or fingers between the punching plate and the punching bar.
42
Bed cover(left)
Fixing Screw①
Support plate
Fixing Screw③
Sub-support plate
for left, right
adjustment
Bed cover
(right)
[Figure 91]
Fixing Screw②
Needle plate
support cover
[Figure 92]
Needle plate
support cover
[Figure 93]