ENABLING THE BOILER
1,5 ... 2 bar
LTALW7H000211a
LT.AL.W7H.000.211
•
R
LT.AL.W7H.000.223
LTALW7H000223a
•
The boiler will now automatically start operating. See par. 3.2
for an explanation of the codes on the display.
LT.AL.W7H.000.212
LTALW7H000212a
Error message
If the boiler does not start operating and an error message is
displayed, consult the error table in par. 4.1 and, if necessary,
consult the installer.
R
LT.NL.W6H.000.079
LTNLW6H000079A
22
Remeha Avanta Plus
•
Check the boiler water pressure. If the water pressure
is less than 1 bar, the system has to be topped up
with water, see par.5.1.
Switch on the boiler at the fused spur unit; the boiler will
run the start-up program.
- A display test will briefly appear showing all segments of
the display.
f[ xx software version;
p[ xx parameter version;
- A venting cycle of 2 minutes now follows, the version
numbers will be displayed alternately;
- Next, the following will appear in the display;
[1 ; boiler is ventilating;
[2 ; boiler is igniting;
[4 ; boiler is operating for DHW;
[7 ; boiler pump is running after heating DHW;
[0 ; boiler is stand-by.
Set the room thermostat to the desired room temperature.